Focus T41, T41F, T43, T43F, T44F
by Elamedical
510(k) K904255
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK904255 | Date18 Jan 1991 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DTB
- Device Class
- Class III
- Regulation
- 21 CFR Part 870.3680
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The Focus T41, T41F, T43, T43F, and T44F are permanent pacemaker electrodes designed for implantation in the cardiovascular system. These devices are intended to deliver electrical stimulation to the heart, ensuring proper pacing and rhythm regulation in patients with bradycardia or other conduction disorders.
These electrodes are supplied sterile and intended for single-use implantation by qualified healthcare professionals. They are classified as Class III medical devices under FDA regulations and have received 510(k) clearance through a traditional review process. The devices are compatible with MRI environments under specific conditions and are available in multiple configurations to accommodate various patient anatomies and clinical needs.
Other devices from Ela Medical, Inc.
Questions
AI-generated answers, 18 Sep 2026
Are these pacemaker electrodes reusable or intended for single-use, and how should they be handled before implantation?
The Focus T41, T41F, T43, T43F, and T44F electrodes are sterile and intended for single-use only. They come pre-packaged to maintain sterility and must be used immediately after opening by qualified healthcare professionals during implantation. Reuse is not recommended or supported by the manufacturer.
What sizes or models are available, and how do I determine which one is best suited for my patient?
The Focus series includes four models: T41, T41F, T43, T43F, and T44F, each designed with different configurations to accommodate varying patient anatomies and clinical needs. The ‘F’ variants (e.g., T41F) likely denote specific features like fixation mechanisms or lead designs. Selection should be based on the patient’s anatomy, implantation site (e.g., right ventricle or atrium), and the physician’s preference for pacing stability. Consult the manufacturer’s documentation or a product guide for detailed sizing and compatibility.
Can these electrodes be used in patients who require MRI scans, and if so, are there any restrictions?
Yes, the Focus T-series electrodes are compatible with MRI environments under specific conditions. However, the exact parameters (e.g., MRI machine type, field strength, and imaging sequences) must be followed to ensure safety. Always verify the manufacturer’s MRI safety guidelines and consult radiology staff before proceeding, as improper use could pose risks to the patient or device.
How were these devices approved by the FDA, and what does the ‘510(k) clearance’ mean for clinicians?
The Focus T-series electrodes received FDA 510(k) clearance through a traditional review process, meaning they were determined to be substantially equivalent to a legally marketed predicate device (a previously approved pacemaker electrode). This classification ensures they meet FDA safety and effectiveness standards for permanent pacemaker electrodes. Clinicians can rely on this approval as evidence of regulatory scrutiny, though individual cases should still follow standard implantation protocols.
What storage conditions are recommended for these electrodes before use?
While the data does not specify exact storage conditions, all sterile single-use medical devices—including these electrodes—typically require protection from moisture, extreme temperatures, and physical damage before use. Store them in their original, sealed packaging in a clean, dry environment as directed by the manufacturer’s instructions for use (IFU). Avoid exposure to direct sunlight or humidity, which could compromise sterility.