# Force Feedback 475006

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/force-feedback-475006>
- Manufacturer: [Intuitive Surgical, Inc.](https://devicerts.com/manufacturers/intuitive-surgical-inc) (United States)
- Device class: Class II (US FDA)
- FDA product code: NAY
- GMDN: Robotic surgical needle holder, reusable (64421)

## Registrations and authorizations

- **GUDID** · GUDID listing · United States · UDI-DI 00886874120705 · listed 2024-03-21 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K232610 · decision 2024-03-14 · decision SESE · status: Active · from GUDID

## Recalls

- Z-2310-2026 · Class II · ongoing · initiated 2026-04-24: Due to unintentionally activated near infrared handheld camera when attempting to turn off illumination during normal clinical workflow transitions, particularly when switching from the handheld camera to the robotic endoscope.
- Z-1355-2026 · Class II · ongoing · initiated 2025-12-30: Robotic-assisted surgical system has Viewer Display manufactured with outdated firmware, may result in loss of one display-loss of 3D surgical field (depth perception) but 2D maintained, or loss of both displays-complete visualization loss, without fault, instruments remain active, could lead to instrument contact with tissue, resulting in injury/bleeding; may require alternate surgical modality.
- Z-1428-2026 · Class II · ongoing · initiated 2025-11-17: An error event following the release of a software version for the surgical system that can result in loss of user interface content on an external monitor or tower monitor.
- Z-1232-2026 · Class II · ongoing · initiated 2025-11-07: Due to a software implementation error that allowed instruments arms failing an important diagnostic test to remain in clinical use. This test was supposed to be used to detect Universal Surgical Manipulator insertion axis ball screws that exhibit the symptoms of being bent and misaligned which is a precursor to potential ball screw fatigue failure/fraction
- Z-1325-2025 · Class II · ongoing · initiated 2025-02-26: Due to an increase in complaints concerning foot tray pedal spring failing resulting in the pedal remaining pressed
- Z-0964-2026 · Class II · ongoing · initiated 2024-08-21: Surgical system Error 23062 due to connector1) Partially damaged "Potential problem with ergonomics: Disable - Retry " or 2) Failed "Disable Ergonomics: Viewer, headrest, armrest, and pedal tray position cannot be adjusted until da Vinci is restarted. Contact Technical Support to report the issue: Cancel-Disable" ergonomics locked until motor replaced; may lead to delay/aborted/alternate procedure

## Identity

- Trade name: Force Feedback [FDA GUDID (AccessGUDID)]
- Generic name: Robotic surgical needle holder, reusable [FDA GUDID (AccessGUDID)]
- Model / reference: 475006 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00886874120705 [FDA GUDID (AccessGUDID)]
- FDA product code: NAY [FDA GUDID (AccessGUDID)]
- GMDN term: Robotic surgical needle holder, reusable (64421) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 876.1500 [FDA GUDID (AccessGUDID)]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Clinical & Handling

- Sterilisation method: Moist Heat or Steam Sterilization [FDA GUDID (AccessGUDID)]

## Dimensions & Sizes

- Size: Outer Diameter — 8 Millimeter [FDA GUDID (AccessGUDID)]

## Properties

- Sterilise before use: Yes [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [FDA GUDID (AccessGUDID)]
- Contains latex: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Force Feedback 475006, Intuitive Surgical, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/force-feedback-475006 (data as of 2026-11-17).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-17
- JSON: <https://devicerts.com/devices/force-feedback-475006.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/force-feedback-475006
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.