Skip to content

Fracture Risk Assessment Option for Pixi Bone Densitometers

by Lunar Corp.

510(k) K983262

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK983262 Date18 Nov 1998ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
KGI
Device Class
Class II
Regulation
21 CFR Part 892.1170
Advisory Committee
Radiology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a software accessory for bone densitometers, classified as a densitometer under FDA regulation 892.1170. It evaluates fracture risk by applying World Health Organization (WHO)-defined criteria to patient T-score values derived from bone density scans, aiding in osteoporosis diagnosis and fracture risk assessment.

The Fracture Risk Assessment Option is designed for use in clinical radiology settings and operates as a supplementary tool to existing Pixi bone densitometers. It is a non-sterile, reusable software solution, supplied as part of the densitometer system. The device holds an FDA 510(k) clearance (K983262) under the Radiology Advisory Committee, with no third-party involvement. Compliance is governed by FDA regulation 892.1170, and the product code is KGI.

Other devices from Lunar

See all devices from Lunar →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical setting is the Fracture Risk Assessment Option designed for, and how does it integrate with existing equipment?

    The Fracture Risk Assessment Option is specifically designed for use in clinical radiology settings. It functions as a supplementary software tool that integrates directly with existing Pixi bone densitometers, enhancing their capability to evaluate fracture risk by applying WHO-defined criteria to T-score data from bone density scans.

  • Is this software reusable or single-use, and what are its sterility and supply details?

    The Fracture Risk Assessment Option is a non-sterile, reusable software solution. It is supplied as part of the densitometer system, meaning no additional packaging or sterilization is required—it is already integrated and ready for use with compatible Pixi bone densitometers.

  • How is the regulatory status of this device determined, and which advisory committee was involved in its clearance?

    This device holds FDA 510(k) clearance (K983262) under the Radiology Advisory Committee (RA). The clearance was granted as substantially equivalent to a predicate device, following review by the FDA’s Radiology Advisory Committee, with no third-party involvement in the process.

  • What types of bone densitometers is this software compatible with, and how does it assist in clinical decision-making?

    The Fracture Risk Assessment Option is compatible with Pixi bone densitometers, as indicated by the listed registration numbers. It aids clinical decision-making by analyzing T-score values from bone density scans and applying WHO-defined criteria to assess fracture risk, helping clinicians diagnose osteoporosis and evaluate patient risk more effectively.