Freeman Acetabular Cup
510(k) K852699
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK852699 | Date5 Sep 1985 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- KWA
- Device Class
- Class III
- Regulation
- 21 CFR Part 888.3330
- Advisory Committee
- Orthopedic
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 18 Sep 2026
The Freeman Acetabular Cup is a semi-constrained, metal, uncemented acetabular component for hip prostheses. It is designed to replace the damaged or diseased acetabulum in total hip arthroplasty, providing a stable bearing surface for the femoral head.
This device is intended for use in orthopedic surgical settings and is supplied as a reusable surgical implant. It is classified as a Class III medical device under FDA regulation 888.3330 and received FDA 510(k) clearance under the KWA product code. Multiple sizes and variants are available, as indicated by the associated registration numbers, and it is regulated under the Orthopedic advisory committee.
Other devices from Advanced Biosearch Assn.
Questions
AI-generated answers, 18 Sep 2026
What types of hip surgeries is the Freeman Acetabular Cup designed for, and how does its semi-constrained design benefit patients?
The Freeman Acetabular Cup is specifically designed for total hip arthroplasty (replacement surgery) to replace a damaged or diseased acetabulum. Its semi-constrained metal construction provides a stable bearing surface for the femoral head, which helps reduce dislocation risk while allowing some flexibility for natural hip movement. This design is particularly useful in cases where additional stability is needed without sacrificing full range of motion.
Is the Freeman Acetabular Cup reusable or single-use, and what does that mean for surgical planning?
The Freeman Acetabular Cup is supplied as a reusable surgical implant, meaning it is intended for multiple uses after proper sterilization and cleaning between procedures. This allows hospitals to optimize inventory while ensuring consistent performance across surgeries. However, reuse requires adherence to strict sterilization protocols to maintain safety and functionality.
How many sizes and variants of the Freeman Acetabular Cup are available, and how do I determine the correct size for a patient?
The Freeman Acetabular Cup comes in multiple sizes and variants, as indicated by the listed registration numbers (e.g., 8043792, 3020282716, etc.). The correct size is determined by preoperative imaging and measurements of the patient’s acetabulum, typically by an orthopedic surgeon or surgical planner. The manufacturer’s sizing guides or surgical planning software should be consulted to match the patient’s anatomy with the appropriate cup variant.
What regulatory pathway was followed for FDA clearance of the Freeman Acetabular Cup, and what does that mean for clinicians?
The Freeman Acetabular Cup received FDA 510(k) clearance under the Traditional pathway, with a decision of *Substantially Equivalent* (SESE) to a predicate device. This means the FDA determined it has the same intended use and technological characteristics as a previously cleared device, ensuring it meets safety and effectiveness standards. Clinicians can rely on this clearance as evidence of regulatory scrutiny, though individual surgical decisions should still follow evidence-based protocols.
How should the Freeman Acetabular Cup be stored to maintain its integrity before use?
Since the Freeman Acetabular Cup is a reusable implant, it must be stored in a clean, dry, and protected environment to prevent contamination or damage. Sterilization packaging (e.g., peel pouches or trays) should be used when not in active use, and storage should comply with hospital infection control protocols. Always follow the manufacturer’s instructions for cleaning, sterilization, and storage to ensure longevity and safety.