Fujinon G5 Duodenoscopes ED-450XT5, ED-250XT5
510(k) K042076
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK042076 | Date18 Nov 2004 | StatusActive |
Recalls
-
- Terminated Z-1864-2016
- Terminated Z-1863-2016
- Terminated Z-1860-2016
This correction is in response to publicized reports of multi-drug resistant bacteria on endoscopes used for Endoscopic Retrograde Cholangiopancreatogram (ERCP) procedures.
-
- Terminated Z-2778-2015
The suction button on the ED-530XT endoscope may become lodged (stuck) in the active position following the use of x-ray contrast agents during ERCP procedures.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Full name
- Fujinon G5 Duodenscopes; G5 Duodenoscopes, Ed-450XT5, Ed-250XT5
- 510(k) Number
- FDA Product Code
- FDT
- Models / Variants
- Device Class
- Class II
- Regulation
- 21 CFR Part 876.1500
- Advisory Committee
- Gastroenterology, Urology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The Fujinon G5 Duodenoscopes (ED-450XT5, ED-250XT5) are flexible, side-viewing duodenoscopes designed for visualization and diagnostic procedures of the upper digestive tract, including the duodenum. These devices incorporate distal CCD sensors to capture high-resolution optical images, enabling detailed examination of anatomical structures and pathological conditions. The ED-450XT5 features a large working channel, while the ED-250XT5 provides a 100-degree field of view for enhanced precision during procedures.
These duodenoscopes are intended for use in clinical settings such as gastroenterology and urology, where they are employed for diagnostic and therapeutic interventions. Supplied as reusable medical devices, they require proper cleaning, disinfection, and sterilization protocols to maintain safety and functionality. The devices are classified under FDA regulation 876.1500 and hold a 510(k) clearance, ensuring compliance with U.S. regulatory standards for flexible/rigid duodenoscopes. Storage and handling must adhere to manufacturer guidelines to preserve performance and sterility.
Other devices from Fujinon, Inc.
Questions
AI-generated answers, 1 Oct 2026
What are the Fujinon G5 Duodenoscopes (ED-450XT5, ED-250XT5) used for?
The Fujinon G5 Duodenoscopes are designed for visualization and diagnostic procedures of the upper digestive tract, including the duodenum. The ED-450XT5 features a large working channel, making it suitable for therapeutic interventions alongside diagnostic imaging, while the ED-250XT5 offers a 100-degree field of view for enhanced precision during examinations. These devices are commonly used in gastroenterology and urology for both diagnostic and therapeutic purposes.
Are the Fujinon G5 Duodenoscopes single-use or reusable?
The Fujinon G5 Duodenoscopes are reusable medical devices. To maintain safety and functionality, they require proper cleaning, disinfection, and sterilization following manufacturer guidelines. Reuse is only permissible when these protocols are strictly adhered to, ensuring the device remains sterile and operational for subsequent procedures.
What distinguishes the ED-450XT5 from the ED-250XT5 in terms of functionality?
The primary distinction lies in their design features: the ED-450XT5 is equipped with a large working channel, which allows for easier insertion of therapeutic instruments during procedures. In contrast, the ED-250XT5 provides a 100-degree field of view, offering enhanced precision and a broader perspective during diagnostic examinations. Both models incorporate distal CCD sensors for high-resolution imaging.
How should these duodenoscopes be stored to maintain performance and sterility?
Storage and handling of the Fujinon G5 Duodenoscopes must follow the manufacturer’s guidelines to preserve performance and sterility. After cleaning, disinfection, and sterilization, they should be stored in a clean, dry environment, protected from physical damage and contamination. The devices should be kept in their original packaging or a designated storage case to prevent exposure to dust, moisture, or other contaminants that could compromise their integrity.
What regulatory compliance does the Fujinon G5 Duodenoscope hold?
The Fujinon G5 Duodenoscopes (ED-450XT5, ED-250XT5) are classified under FDA regulation 876.1500 and hold a 510(k) clearance, indicating they are deemed substantially equivalent to a legally marketed predicate device. This clearance ensures compliance with U.S. regulatory standards for flexible/rigid duodenoscopes, confirming their safety and effectiveness for intended clinical use.