FUJINON ULTRASONIC ENDOSCOPE AND PROCESSOR - Su-700

by Fujinon, Inc.

510(k) K063847

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK063847 Date1 Mar 2007ClearedStatusActive

Recalls

1 recall · FDA

    • Terminated Z-2706-2017 FDA Class II initiated 17 Feb 2017

    Fujifilm is recalling multiple endoscopes after a retrospective review.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
FDS
Models / Variants
Su-700
Device Class
Class II
Regulation
21 CFR Part 876.1500
Advisory Committee
Gastroenterology, Urology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a flexible ultrasonic endoscope system designed for endoscopic ultrasound imaging. It combines an ultrasonic endoscope with a dedicated processor to visualize the upper digestive tract—including the esophagus, stomach, and duodenum—as well as surrounding submucosal and peripheral organs. The system integrates real-time ultrasound imaging with endoscopic visualization to aid in diagnostic assessment.

The system consists of reusable ultrasonic endoscopes (models EG-530UR and EG-530UT) paired with the SU-700 processor, intended for use in clinical settings such as gastroenterology and urology. Supplied sterile or non-sterile based on procedural requirements, the endoscopes are classified as Class II devices under FDA regulations (K063847, 510(k) clearance). Compatibility with MRI environments is not specified, and proper cleaning, disinfection, or sterilization protocols must be followed per manufacturer guidelines.

Other devices from Fujinon, Inc.

See all devices from Fujinon, Inc. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical specialties is this ultrasonic endoscope system primarily used in, and how does it combine imaging modalities to aid diagnosis?

    The Fujinon Ultrasonic Endoscope and Processor system (models EG-530UR, EG-530UT, and SU-700) is primarily used in gastroenterology and urology, as indicated by its advisory committee classification. It combines real-time ultrasound imaging with endoscopic visualization to provide detailed visualization of the upper digestive tract (esophagus, stomach, duodenum) and surrounding submucosal or peripheral organs. This dual-modality approach helps clinicians assess anatomical structures and pathologies more comprehensively than traditional endoscopy alone.

  • Are the ultrasonic endoscopes (EG-530UR/EG-530UT) single-use or reusable, and what sterilization or cleaning requirements apply?

    The ultrasonic endoscopes (models EG-530UR and EG-530UT) are reusable devices, as stated in the device description. They must be cleaned, disinfected, or sterilized according to manufacturer guidelines to ensure safety and functionality. The data does not specify sterilization methods, so adherence to Fujinon’s protocols is critical to maintain device integrity and prevent cross-contamination.

  • How is the system supplied, and can the endoscopes be obtained in sterile or non-sterile configurations?

    The system is supplied with reusable ultrasonic endoscopes (EG-530UR/EG-530UT) paired with the SU-700 processor. The endoscopes can be obtained in either sterile or non-sterile configurations depending on procedural requirements, as noted in the description. Sterility is not a fixed attribute but rather a customizable option to align with clinical workflows (e.g., sterile for minimally invasive procedures, non-sterile for routine cleaning/reuse).

  • What regulatory pathway was followed for FDA clearance of this device, and what does the ‘GU’ advisory committee designation indicate?

    The Fujinon Ultrasonic Endoscope and Processor received FDA clearance via a 510(k) submission (K063847), classified as substantially equivalent under the traditional review pathway. The ‘GU’ advisory committee designation refers to the Gastroenterology and Urology (GU) Panel, which reviewed the submission to ensure the device met safety and effectiveness standards for its intended use in these specialties. This panel evaluates devices like gastroscopes and accessories, aligning with the system’s primary applications.