Fusion Bx (2.0) is a medical device (EU MDR Class IIa; FDA Class II; FDA product code LLZ, System, Image Processing, Radiological; EMDN category picture archiving and communication systems) made by Focal Healthcare Inc, registered in EUDAMED on 9 Mar 2026 (Basic UDI-DI 62805585801SF), cleared under FDA 510(k) K181290 on 15 Jun 2018 (1 earlier submission) and listed in FDA GUDID since 31 Aug 2018 (UDI-DI 00628055858010), active as of 24 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 24 Oct 2026

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, FDA 510(k), GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number62805585801SF Basic UDI-DI 00628055858010UDI-DIDate9 Mar 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00628055858010 UDI-DI Date31 Aug 2018ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k) 510(k) NumberK181290 Date15 Jun 2018IssuedStatusActive

Official records

From the FDA record

Device description
Fusion Bx 2.0 is designed to display the 2D live video received from commercially available ultrasound machines and use this 2D video to reconstruct a 3D ultrasound image volume. The system is designed to work with clinicians’ existing ultrasound machines, transrectal ultrasound (TRUS) probes, commercially available needles, needle guides/templates and needle gun combination. Additional software features include patient data management, multi-planar reconstruction, segmentation, image measurements and 3D image registration. Fusion Bx 2.0 offers the physician additional 3D information for assessing prostate abnormalities, planning and implementing biopsy procedures. The additional image processing features are generated with minimal changes to previous TRUS probe-based procedures, and the physician always has access to the live 2D ultrasound image during prostate assessment or biopsy procedure.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 62805585801SF registered 9 Mar 2026 Active
  • FDA 510(k) K181290 decided 15 Jun 2018 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00628055858010 listed 31 Aug 2018 Listed

Timeline

4 dated events

  1. Cleared FDA 510(k) K153166
  2. Cleared FDA 510(k) K181290
  3. Listed FDA GUDID 00628055858010
  4. Registered EUDAMED 62805585801SF

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • United States FDA 510(k) Active
  • European Union CE/MDR Active

Specification

EUDAMED · 510(k) · GUDID

Generic name
Radiology picture archiving and communication system workstation
Model / reference
2.0
Primary DI / UDI-DI
00628055858010
Basic UDI-DI
62805585801SF
Direct marketing DI
00628055858010
FDA product code
LLZ
EMDN code
Z110603 Picture archiving and communication systems
GMDN term
Radiology picture archiving and communication system workstation
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.2050
EU registration type
Standard device
EU market of registration
Belgium
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
CA-MF-000050812
Authorised representative
Obelis s.a. BE-AR-000000106

Similar devices in this category

Other devices filed under PICTURE ARCHIVING AND COMMUNICATION SYSTEMS.

Other devices from Focal Healthcare Inc

  • Fusion Bx 1.1

    Class II

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)