Fuzzy Type Digital Blood Pressure Monitor HD-1000S & HD-2000F

by Jawon Medical Co., Ltd.

510(k) K983855

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK983855 Date17 Nov 1998ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Fuzzy Type Digital Blood Pressure Monitor, Model #'s Hd-1000S & Hd-2000F
510(k) Number
FDA Product Code
DXN
Device Class
Class II
Regulation
21 CFR Part 870.1130
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Fuzzy Type Digital Blood Pressure Monitor HD-1000S & HD-2000F is a non-invasive, oscillometric sphygmomanometer designed for brachial blood pressure measurement. It employs an air pump, electronic valve, and cuff to automatically inflate and deflate, measuring systolic and diastolic pressure via oscillometric principles.

These devices are microprocessor-controlled and intended for clinical or home use, supplied as reusable medical instruments. They are classified under product code DXN as Class II devices with Special Controls, and hold an FDA 510(k) clearance (K983855) for substantial equivalence. No sterility or single-use designation is specified in the regulatory data.

Other devices from Jawon Medical Co., Ltd.

See all devices from Jawon Medical Co., Ltd. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Are these blood pressure monitors meant for one-time use or can they be reused in a clinical setting?

    The Jawon Medical Co., Ltd. Fuzzy Type Digital Blood Pressure Monitors (HD-1000S & HD-2000F) are explicitly labeled as reusable medical instruments in the regulatory data. Since no sterility or single-use designation is specified, they are intended for repeated use in clinical or home settings, provided proper cleaning and maintenance protocols are followed.

  • What types of blood pressure measurements do these devices provide, and how do they work?

    These monitors are non-invasive, oscillometric sphygmomanometers, meaning they measure blood pressure by detecting oscillations in the cuff as it inflates and deflates automatically. They provide systolic and diastolic pressure readings via microprocessor-controlled inflation/deflation, making them suitable for both clinical and home use without manual adjustments.

  • What regulatory pathway was followed for FDA clearance, and which advisory committee reviewed this device?

    The Fuzzy Type Digital Blood Pressure Monitor (HD-1000S & HD-2000F) received FDA 510(k) clearance (K983855) under the Traditional 510(k) review pathway, determined to be substantially equivalent to a predicate device. The review was conducted by the Cardiovascular (CV) Advisory Committee, and the device falls under product code DXN (Class II, Special Controls).

  • Are there multiple models available, and if so, how do they differ?

    Yes, there are two models: the HD-1000S and the HD-2000F. While the regulatory data does not specify functional differences, the naming convention suggests potential variations in features (e.g., display, connectivity, or additional metrics). Both share the same oscillometric measurement principle and reusable design, so compatibility with clinical workflows would depend on specific clinical needs.