Garbin 00 (1058180) is a portable electric ventilator (FDA Class II) made by Respironics Inc., cleared under FDA 510(k) K083526 on 13 Mar 2009 and listed in FDA GUDID since 22 Oct 2015 (UDI-DI 00606959022768), active as of 23 Oct 2026. 8 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
3 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00606959022768 | Date22 Oct 2015 | StatusListed |
| United States | FDA 510(k)SESE | NumberK083526 | Date13 Mar 2009 | StatusActive |
Official records
- AccessGUDID record 00606959022768
- FDA 510(k) database K083526
From the FDA record
- Device description
- Garbin Ventilator (Trilogy 100)
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K083526 decided 13 Mar 2009 Active
- FDA GUDID UDI-DI 00606959022768 listed 22 Oct 2015 Listed
Recalls
-
- Ongoing Z-0882-2023
- Ongoing Z-0884-2023
The replacement silicone sound abatement foam installed into some Trilogy 100 and Trilogy 200 devices may separate from the plastic backing to which it is attached. If this were to happen, the foam could potentially block air inlet, which could result in a reduction in delivered therapy volume or pressure and could cause the device to alarm.
-
- Ongoing Z-1956-2021
The polyester-based polyurethane (PE-PUR) foam may degrade into particles which may enter the devices air pathway and be ingested or inhaled by the user, and the PE-PUR foam may off-gas certain chemicals.
-
- Terminated Z-1065-2016
Software Issue
-
- Terminated Z-1143-2014
Internal testing revealed a potentially defective component on the power management board that could affect the function of certain Trilogy Ventilators resulting in loss of therapy to patients.
-
- Terminated Z-2024-2012
The specified Trilogy units are being recalled because of the potential for a faulty component in the power supply.
-
- Terminated Z-0296-2012
Trilogy 100, 200 and 202 units are being recalled due to low impeller press-force used during the manufacturing process. If the press force were low enough, theoretically the impeller could move up the shaft and come into contact with the inside of the blower housing/impeller enclosure. This may impact therapy.
-
- Terminated Z-1896-2010
It is possible that the battery could electrically short, resulting in a potential for fire or a thermal event.
Timeline
- Cleared FDA 510(k) K083526
- Recall initiated FDA recalls Z-1896-2010
- Recall initiated FDA recalls Z-0296-2012
- Recall initiated FDA recalls Z-2024-2012
- Recall initiated FDA recalls Z-1143-2014
- Listed FDA GUDID 00606959022768
- Recall initiated FDA recalls Z-1065-2016
- Recall initiated FDA recalls Z-1956-2021
- Recall initiated FDA recalls Z-0882-2023
- Recall initiated FDA recalls Z-0884-2023
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Garbin
- Generic name
- Portable electric ventilator
- Model / Ref / Catalog
- 00, 1058180
- Primary DI / UDI-DI
- 00606959022768
- 510(k) Number
- FDA product code
- DQA, CBK, NOU
- GMDN term
- Portable electric ventilator
- Device class
- Class II
- Regulation number
- 870.2700, 868.5895
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code DQA (Oximeter).
- Kit, Pronto Pulse CO-Oximeter DCIP SC-200 3581 by MASIMO CORPORATION
- SPO2 FINGER PROBES by Medical Cables, Inc.
- PULSEMATE BX-5 by Colin Medical Instruments Corp.
- LNCS OXIMETRY SENSORS by MASIMO CORPORATION
- T12S TELEMETRY TRANSMITTER by MORTARA INSTRUMENT, INC.
- Solairs S200A-090101 by Solaris Medical Technology, Inc.
- BERRY®贝瑞 BM1000A by SHANGHAI BERRY ELECTRONIC TECH CO., LTD.
- EPIC SPO2 FINGER SENSOR, MODEL E403-09, E412-09 AND EPIC OXIMETER CABLE, MODEL E710-09 by Epic Medical Equipment Services, Inc.
- Fingertip Pulse Oximeters M70, M70A, M70B, M70C, M70D by GUANGDONG BIOLIGHT MEDITECH CO., LTD
- OHMEDA 4700 OXICAP MONITOR by Ohmeda Medical