GEM Premier 4000 00025000000
by Instrumentation Laboratory Company
GEM Premier 4000 00025000000 is a blood gas/haemoximetry analyser IVD (FDA Class II; FDA product code CHL, Electrode Measurement, Blood-Gases (Pco2, Po2) and Blood Ph) made by Instrumentation Laboratory Company, cleared under FDA 510(k) K133407 on 13 Jan 2014 (2 earlier submissions) and listed in FDA GUDID since 23 Sep 2016 (UDI-DI 08426950452591), active as of 23 Oct 2026.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number08426950452591 | Date23 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK133407 | Date13 Jan 2014 | StatusActive |
Official records
- AccessGUDID record 08426950452591
- FDA 510(k) database K133407
- FDA 510(k) database K112995
- FDA 510(k) database K093623
From the FDA record
- Device description
- GEM Premier 4000
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K133407 decided 13 Jan 2014 Active
- FDA GUDID UDI-DI 08426950452591 listed 23 Sep 2016 Listed
Recalls
-
- Terminated Z-2803-2011
- Terminated Z-2804-2011
- Terminated Z-2805-2011
- Terminated Z-2806-2011
K+ results on the GEM Premier 4000 are too low when compared to a reference analyzer, with biases exceeding allowable error claim of a 0.5 moUL
-
- Terminated Z-2165-2011
Measurement (amperometric) spike can occur early in cartridge life on the glucose and lactate sensors during patient blood analysis, leading to erroneously high results
Timeline
- Cleared FDA 510(k) K093623
- Recall initiated FDA recalls Z-2165-2011
- Recall initiated FDA recalls Z-2803-2011
- Recall initiated FDA recalls Z-2804-2011
- Recall initiated FDA recalls Z-2805-2011
- Recall initiated FDA recalls Z-2806-2011
- Cleared FDA 510(k) K112995
- Cleared FDA 510(k) K133407
- Listed FDA GUDID 08426950452591
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- GEM Premier 4000
- Generic name
- Blood gas/haemoximetry analyser IVD, laboratory
- Model / Ref / Catalog
- 00025000000
- Primary DI / UDI-DI
- 08426950452591
- FDA product code
- CHL
- GMDN term
- Blood gas/haemoximetry analyser IVD, laboratory
- Device class
- Class II
- Regulation number
- 862.1120
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code CHL (ELECTRODE MEASUREMENT, BLOOD-GASES (PCO2, PO2) AND BLOOD PH).
- OPTI CCA-TS, B-LAC CASSETTE MODEL BP7561 by OPTI MEDICAL SYSTEMS INC.
- ABL SYSTEM 625, 615, 605 by RADIOMETER AMERICA, INC.
- BLOOD GAS MIXTURE by Swisco, Inc.
- OPTI Analyzer CCA TS 1 GD7013 by OPTI MEDICAL SYSTEMS INC.
- IRMA BLOOD ANALYSIS SYSTEM WITH OPTIONAL MULTI-USE CARTRIDGE by Diametrics Medical, Ltd.
- ABL90 by Radiometer Medical ApS
- CIBA CORNING 400 SYSTEM by Ciba Corning Diagnostics Corp.
- CIBA CORNING MODEL 238 PH/ BLOOD GAS ANALYZER by Ciba Corning Diagnostics Corp.
- TECHNICON BGII ANALYZER by Technicon Instruments Corp.
- AVL OPTI R ANALYZER by Avl Scientific Corp.