# GEM Premier 4000 00025000000R

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/gem-premier-4000-00025000000r>
- Manufacturer: [Instrumentation Laboratory Company](https://devicerts.com/manufacturers/instrumentation-laboratory-company) (United States)
- Device class: Class II (US FDA)
- FDA product code: CHL, CIG, CEM
- GMDN: Blood gas/haemoximetry analyser IVD, laboratory (56663)

## Registrations and authorizations

- **GUDID** · GUDID listing · United States · UDI-DI 08426950947370 · listed 2016-09-23 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K133407 · decision 2014-01-13 · decision SESE · status: Active · from GUDID
- **GUDID** · FDA 510(k) · United States · K112995 · decision 2012-05-03 · decision SESE · status: Active · from GUDID
- **GUDID** · FDA 510(k) · United States · K093623 · decision 2010-06-18 · decision SESE · status: Active · from GUDID

## Recalls

- Z-2803-2011 ·  · terminated · initiated 2011-05-31 · matched through shared submission K093623, may concern other models: K+ results on the GEM Premier 4000 are too low when compared to a reference analyzer, with biases exceeding allowable error claim of a 0.5 moUL
- Z-2804-2011 ·  · terminated · initiated 2011-05-31 · matched through shared submission K093623, may concern other models: K+ results on the GEM Premier 4000 are too low when compared to a reference analyzer, with biases exceeding allowable error claim of a 0.5 moUL
- Z-2805-2011 ·  · terminated · initiated 2011-05-31 · matched through shared submission K093623, may concern other models: K+ results on the GEM Premier 4000 are too low when compared to a reference analyzer, with biases exceeding allowable error claim of a 0.5 moUL
- Z-2806-2011 ·  · terminated · initiated 2011-05-31 · matched through shared submission K093623, may concern other models: K+ results on the GEM Premier 4000 are too low when compared to a reference analyzer, with biases exceeding allowable error claim of a 0.5 moUL
- Z-2165-2011 ·  · terminated · initiated 2011-02-14 · matched through shared submission K093623, may concern other models: Measurement (amperometric) spike can occur early in cartridge life on the glucose and lactate sensors during patient blood analysis, leading to erroneously high results

## Identity

- Trade name: GEM Premier 4000 [FDA GUDID (AccessGUDID)]
- Generic name: Blood gas/haemoximetry analyser IVD, laboratory [FDA GUDID (AccessGUDID)]
- Model / Ref / Catalog: 00025000000R [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 08426950947370 [FDA GUDID (AccessGUDID)]
- 510(k) Number: K093623 [FDA GUDID (AccessGUDID)]; K112995 [FDA GUDID (AccessGUDID)]; K133407 [FDA GUDID (AccessGUDID)]
- FDA product code: CHL [FDA GUDID (AccessGUDID)]
- GMDN term: Blood gas/haemoximetry analyser IVD, laboratory (56663) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 862.1120 [FDA GUDID (AccessGUDID)]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [FDA GUDID (AccessGUDID)]
- Contains latex: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: GEM Premier 4000 00025000000R, Instrumentation Laboratory Company. deviCERTS medical device catalogue. https://devicerts.com/devices/gem-premier-4000-00025000000r (data as of 2026-11-23).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-23
- Statuses computed as of: 2026-11-23
- JSON: <https://devicerts.com/devices/gem-premier-4000-00025000000r.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.