Global Unite 1407-20-102
Ref 1407-20-102Model GLOBAL UNITE Reverse Fracture Epiphysis
Global Unite 1407-20-102 (140720102) is a device classified as Class III in the EU and Class II in the US made by Depuy (Ireland), registered in EUDAMED on 23 Dec 2025 (Basic UDI-DI 0603295a003098P), cleared under FDA 510(k) K170748 on 11 Jan 2018 and listed in FDA GUDID since 15 Mar 2018 (UDI-DI 10603295446675), active as of 7 Nov 2026. 8 FDA recalls are linked to it.
Active
CE MDR 510(k)
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0603295a003098P 10603295446675 | Date23 Dec 2025 | StatusActive |
| United States | GUDID listing GUDID | Number10603295446675 | Date15 Mar 2018 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK170748 | Date11 Jan 2018 | StatusActive |
Official records
- EUDAMED public site 0603295a003098P
- AccessGUDID record 10603295446675
- FDA 510(k) database K170748
Across registries
- EUDAMED Basic UDI-DI 0603295a003098P registered 23 Dec 2025 Active
- FDA 510(k) K170748 decided 11 Jan 2018 Active
- FDA GUDID UDI-DI 10603295446675 listed 15 Mar 2018 Listed
Recalls
-
- Terminated Z-0483-2022
- Terminated Z-0486-2022
- Terminated Z-0489-2022
- Terminated Z-0488-2022
- Terminated Z-0485-2022
- Terminated Z-0490-2022
- Terminated Z-0484-2022
- Terminated Z-0487-2022
Stems may have an undersized spigot bore diameter therefore separating the proximal body from the stem may not be possible without surgical delay and/or bone damage
Timeline
- Listed FDA GUDID 10603295446675
- Recall initiated FDA recalls Z-0483-2022
- Recall initiated FDA recalls Z-0486-2022
- Recall initiated FDA recalls Z-0489-2022
- Recall initiated FDA recalls Z-0488-2022
- Recall initiated FDA recalls Z-0485-2022
- Recall initiated FDA recalls Z-0490-2022
- Recall initiated FDA recalls Z-0484-2022
- Recall initiated FDA recalls Z-0487-2022
- Registered EUDAMED 0603295a003098P
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Global Unite
- Generic name
- Reverse shoulder prosthesis body
- Device name
- GLOBAL UNITE Reverse Fracture Epiphysis
- Model / Ref / Catalog
- 1407-20-102, GLOBAL UNITE Reverse Fracture Epiphysis, 140720102
- Primary DI / UDI-DI
- 10603295446675
- Basic UDI-DI
- 0603295a003098P
- 510(k) Number
- FDA product code
- PHX, HSD, KWS
- EMDN code
- P090104010201 Epiphysary humeral components for reverse prostheses - inserts
- GMDN term
- Reverse shoulder prosthesis body
- Device class
- Class III EUDAMEDClass II GUDID
- Regulation number
- 888.3660, 888.3690
- EU registration type
- Standard device
- EU market of registration
- Ireland
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class III | Class II |
Similar devices in this category
Other devices filed under EPIPHYSARY HUMERAL COMPONENTS FOR REVERSE PROSTHESES - INSERTS.
- Easytech Anatomical Shoulder System 314-0034 by FX SOLUTIONS
- Shoulder System 04.01.0119 by Medacta International
- Easytech Anatomical Shoulder System 314-0030 by FX SOLUTIONS
- SMR Shoulder 1360.54.816 by Limacorporate
- SMR System 1365.09.115 by Limacorporate
- Reverse Constrained Humeral Liner P38144135S by Tianjin Zhengtian Medical Instrument Co., Ltd.
- UNIC® E27 221M by EVOLUTIS
- Identity™ Vivacit-E® 110044400 by Zimmer, Inc.
- Identity™ Vivacit-E® 110044360 by Zimmer, Inc.
- Shoulder System 04.01.0123 by Medacta International