Skip to content

GMK Revision Knee SC Liners

by Medacta International S.A.

510(k) K103170

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK103170 Date24 Mar 2011ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
JWH
Device Class
Class II
Regulation
21 CFR Part 888.3560
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The GMK Revision Knee SC Liners are Knee Prosthesis Components designed for use in revision total knee arthroplasty. These liners are intended to restore joint alignment, functional stability, and fixation for revision prosthetic implants, addressing ligament instability and bone defects in complex knee replacements. They are engineered to re-establish anatomical joint positioning and secure implant components within the femur and tibia.

These liners are supplied as single-use, sterile devices for cemented fixation in revision knee procedures. They are classified under FDA product code JWH and were granted 510(k) clearance as substantially equivalent to a predicate device. Sizes and configurations are tailored for revision scenarios, requiring surgical precision for proper placement. Compliance with orthopedic revision standards ensures compatibility with existing Medacta knee systems and revision protocols.

Other devices from Medacta International S.A.

See all devices from Medacta International S.A. →

Questions

AI-generated answers, 20 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Are the GMK Revision Knee SC Liners designed for primary knee replacements, or are they specifically for revision surgeries?

    These liners are exclusively intended for revision total knee arthroplasty, not primary procedures. Their design addresses ligament instability and bone defects common in complex knee replacements, ensuring secure fixation and anatomical alignment for patients undergoing repeat surgeries. The term *revision* in the name and description confirms their specialized use.

  • How are the GMK Revision Knee SC Liners supplied, and what does that mean for surgical workflow?

    They are supplied as single-use, sterile devices, meaning each liner is packaged for one procedure and cannot be reused. This eliminates the need for sterilization between cases, simplifying workflow and reducing contamination risks. The sterile packaging ensures readiness for immediate use in revision surgeries.

  • What types of fixation do these liners support, and how does that affect their use in revision knee procedures?

    The liners are intended for cemented fixation, meaning they are secured to the bone using orthopedic cement during surgery. This method is critical in revision cases, where bone quality may be compromised, as cement provides additional stability to the implant. The design ensures compatibility with Medacta’s revision protocols, which rely on cemented components for reliability.

  • Are these liners compatible with other knee systems, or are they part of a proprietary Medacta revision platform?

    While the liners are engineered to comply with orthopedic revision standards, their primary compatibility is with Medacta’s existing knee systems and revision protocols. The design is tailored for Medacta’s revision scenarios, ensuring seamless integration with their established surgical techniques and implant components. Third-party systems would require validation.

  • How do I determine the correct size or configuration for a patient’s revision knee surgery?

    Sizing and configuration are tailored for complex revision scenarios, requiring surgical precision during placement. The liners are not one-size-fits-all; their design accounts for variable bone defects and ligament instability in repeat knee replacements. Surgeons must follow Medacta’s revision protocols and use intraoperative assessment to select the appropriate liner for the patient’s anatomy and defect characteristics.