Goodwin Lung Line 411010-000
Goodwin Lung Line 411010-000 is a cardioplegia solution administration adaptor (FDA Class II; FDA product code DTR, Heat-Exchanger, Cardiopulmonary Bypass) made by Novosci Corp., cleared under FDA 510(k) K802545 on 16 Jan 1981 and listed in FDA GUDID since 24 Jan 2019 (UDI-DI B0664110100000), active as of 23 Oct 2026.
Active
510(k)
Valid until
No expiry
FDA recalls
None found
Documents
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | NumberB0664110100000 | Date24 Jan 2019 | StatusListed |
| United States | FDA 510(k)SESE | NumberK802545 | Date16 Jan 1981 | StatusActive |
Official records
- FDA 510(k) database K802545
From the FDA record
- Device description
- A sterile device designed to facilitate/regulate the delivery of cardioplegic solution to the heart during a cardiopulmonary bypass procedure by connecting an administration line to a cardioplegia cannula. Also known as a cardioplegia delivery set, it basically consists of tubing [e.g., polyvinyl chloride (PVC)] with connectors. It may have a single lumen or branched multiple-lumen design and include various types of connectors, clamps, and valves, depending on additional intended uses (e.g., venting, recirculation, and/or simultaneous perfusion of vein grafts). This is a single-use device.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K802545 decided 16 Jan 1981 Active
- FDA GUDID UDI-DI B0664110100000 listed 24 Jan 2019 Listed
Timeline
- Cleared FDA 510(k) K802545
- Listed FDA GUDID B0664110100000
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Goodwin Lung Line
- Generic name
- Cardioplegia solution administration adaptor
- Model / Ref / Catalog
- 411010-000
- Primary DI / UDI-DI
- B0664110100000
- 510(k) Number
- FDA product code
- DTR
- GMDN term
- Cardioplegia solution administration adaptor
- Device class
- Class II
- Regulation number
- 870.4240
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code DTR (Heat-Exchanger, Cardiopulmonary Bypass).
- MPS 3 ND Delivery Set w/AA w/106cm (16C) 5ND3103 by QUEST MEDICAL INC
- Coronary Sinus Transducer Interface Cable (Retrograde) 511800R by QUEST MEDICAL INC
- Heat Exchanger Coil by Delta Medical Industries
- VANGUARD Blood cardioplegia Systems (Vanguard 4:1 Blood cardioplegia set); VANGUARD Blood cardioplegia Systems (Vanguard 4:1 Blood cardioplegia set with shunt); VANGUARD Blood cardioplegia Systems (Vanguard 4:1 Blood Cardioplegia Set Mini) by Sorin Group Italia S.R.L.
- VISION BLOOD CARDIOPLEGIA SYSTEM AND EXTRACORPORAL HEAT EXCHANGER WITH GBS COATING by Gish Biomedical, Inc.
- Quantum PureFlow Standard Heat Exchanger High Flow 3/8 W HX55V-S0W by SPECTRUM MEDICAL SRL
- D6ZO Disposable Heat Exchanger by Electromedics, Inc.
- Electromedics Blood Heat Exchanger by Electromedics, Inc.
- Sarns MP4 Cardioplegia Delivery System by 3M Health Care, Sarns
- Pacing Kit, Semi-Floating by Electro-Catheter Corp.