Skip to content

Gore-Tex Vascular Graft, FEP-Ringed

by W. L. Gore & Associates, Inc.

510(k) K842144

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK842144 Date1 Oct 1984ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DYF
Device Class
Class II
Regulation
21 CFR Part 870.3450
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Gore-Tex Vascular Graft, FEP-Ringed is classified as a Prosthesis, Vascular Graft, of less than 6 mm diameter. It is a synthetic vascular graft designed to replace or bypass damaged blood vessels, facilitating blood flow in cardiovascular procedures. Constructed with expanded polytetrafluoroethylene (ePTFE), this graft provides a durable, biocompatible conduit for arterial reconstruction.

This device is supplied sterile and intended for single-use in vascular bypass procedures, including axillobifemoral applications. It is available in multiple configurations, including straight and tapered designs, and is reinforced with removable FEP (fluorinated ethylene propylene) rings to aid in deployment and stability. The graft is regulated under FDA 510(k) clearance (K842144) and falls under Class II medical device classification (DYF). Storage and handling must comply with sterile medical device protocols.

Other devices from W. L. Gore & Associates, Inc.

See all devices from W. L. Gore & Associates, Inc. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Gore-Tex Vascular Graft, FEP-Ringed intended for?

    The Gore-Tex Vascular Graft, FEP-Ringed is a synthetic vascular graft designed to replace or bypass damaged blood vessels, facilitating blood flow in cardiovascular procedures such as axillobifemoral bypass. It is constructed from expanded polytetrafluoroethylene (ePTFE) and is intended for use in arterial reconstruction where a durable, biocompatible conduit is needed.

  • How is the Gore-Tex Vascular Graft, FEP-Ringed supplied and is it reusable?

    The device is supplied sterile and intended for single-use only. It must not be reprocessed or reused, as doing so could compromise sterility, structural integrity, and patient safety. Each graft is designed for one-time implantation during a vascular bypass procedure.

  • What sizes and configurations are available for the Gore-Tex Vascular Graft, FEP-Ringed?

    The graft is available in multiple configurations, including straight and tapered designs, and is reinforced with removable FEP (fluorinated ethylene propylene) rings to aid in deployment and stability. It is classified as a prosthesis for vascular grafts of less than 6 mm diameter, though specific inner diameters and lengths are not detailed in the provided data.

  • What regulatory pathway was used for the Gore-Tex Vascular Graft, FEP-Ringed?

    The device was cleared through the FDA 510(k) process under submission K842144, with a decision date of October 1, 1984. It is classified as a Class II medical device under product code DYF and regulation number 870.3450, and was found substantially equivalent to a predicate device.

  • How should the Gore-Tex Vascular Graft, FEP-Ringed be stored and handled?

    The graft must be stored and handled in accordance with sterile medical device protocols to maintain its sterility and integrity until use. It is supplied sterile, so storage conditions should prevent damage to the packaging and preserve the sterile barrier until the point of implantation.