Skip to content

Gridlock Plating System

by Trilliant Surgical, LLC 3 variants

510(k) K121452

Gridlock Plating System is a medical device (FDA Class II; FDA product code HRS, Plate, Fixation, Bone) made by Trilliant Surgical, LLC, cleared under FDA 510(k) K121452 on 20 Aug 2012, active as of 8 Nov 2026. 2 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

4 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 8 Nov 2026.

Regulatory status

as of registry sync 8 Nov 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK121452 Date20 Aug 2012ClearedStatusActive

Official records

From the FDA record

Received by the FDA
16 May 2012
FDA decision
20 Aug 2012 (Substantially Equivalent)
FDA review time
96 days from receipt to decision
Public document
510(k) summary on file with the FDA

From the FDA 510(k) record K121452 (openFDA), as read on 8 Nov 2026. Quoted as published, gaps included; nothing on this list is generated.

Recalls

4 recalls · FDA

    • Terminated Z-1609-2020 FDA Class II initiated 19 Jul 2018 on shared 510(k) K121452

    Instructions for Use (IFU) and Surgical Cleaning and Sterilization Protocols updated with revised dry time parameters. This recall of IFU occurred in 2018.

    • Terminated Z-2490-2015 FDA Class II initiated 6 Aug 2015

    The affected parts subject to the recall are out of specification, resulting in in the loss of the optimal locking screw functionality of the plates. The thread depth of the screw holes is insufficient, potentially limiting the ability to engage and lock with associated mating locking screws.

    • Terminated Z-2738-2015 FDA Class II initiated 31 Jul 2015

    Gridlock screw driver bits for the Gridlock Plating System were identified to be out of specification and have the potential for shallow engagement between the driver and the screw, resulting in an increased likelihood of stripping screw heads intraoperatively. Specifically, the minor diameter of the drive feature is above the specification, potentially reducing the engagement between the driver and the screw head.

    • Terminated Z-2456-2015 FDA Class II initiated 20 Jul 2015 on shared 510(k) K121452

    The cannulation of the Concave and Convex Reamer Heads may be too small to allow the Guide Pin to freely pass through.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

5 dated events

  1. Cleared FDA 510(k) K121452
  2. Recall initiated FDA recalls Z-2456-2015
  3. Recall initiated FDA recalls Z-2738-2015
  4. Recall initiated FDA recalls Z-2490-2015
  5. Recall initiated FDA recalls Z-1609-2020

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
HRS
FDA applicant
Trilliant Surgical, Ltd.
Device class
Class II
Regulation
21 CFR Part 888.3030
Advisory committee
Orthopedic
FDA decision
SESE Substantially Equivalent

Similar devices

Other devices filed under FDA product code HRS (Plate, Fixation, Bone).

Other devices from Trilliant Surgical, LLC

See all devices from Trilliant Surgical, LLC →