HA FlexTrak
by Philips Medical Systems Nederland B.V. Netherlands EUDAMEDGUDID
Ref 989710006412
Product code LNHEMDN Z1105018099
Regulatory status
Recall ongoing. 39 ongoing FDA recalls. See recalls
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0884838BM474TB | Date31 Mar 2025 | StatusActive |
| United States | GUDID listing GUDID | Number00884838099470 | Date31 Aug 2022 | StatusIn distribution |
Coverage
- Active
- Listed
- Not covered
- European Union
- United States
Recalls
-
- Ongoing Z-3318-2026
- Ongoing Z-3310-2026
- Ongoing Z-3308-2026
- Ongoing Z-3314-2026
When exporting diffusion tensor imaging (DTI) scans from a MR system using the Enhanced MR DICOM format, the exports contain incorrect data (diffusion directions). If the Enhanced MR DICOM export is used in conjunction with third-party software for tractography (e.g. for mapping nerve fiber pathways in the brain), the software will not be able to correctly process the DTI data for reconstruction.
-
- Ongoing Z-3243-2026
- Ongoing Z-3237-2026
- Ongoing Z-3236-2026
- Ongoing Z-3235-2026
A software issue will terminate an examination during the image reconstruction process if the scan parameters are manually adjusted such that reconstruction requirements exceed the available system memory.
-
- Ongoing Z-1955-2026
- Ongoing Z-1968-2026
- Ongoing Z-1960-2026
- Ongoing Z-1966-2026
- Ongoing Z-1956-2026
- Ongoing Z-1954-2026
- Ongoing Z-1969-2026
- Ongoing Z-1961-2026
- Ongoing Z-1967-2026
The potential for stiffness value errors when a specific range of image reconstruction parameters is used in combination with Resoundant's algorithm, leading to the reconstruction voxel size settings in the default MRE scan protocol displaying too small.
-
- Ongoing Z-1215-2026
- Ongoing Z-1210-2026
- Ongoing Z-1205-2026
- Ongoing Z-1204-2026
The potential for stiffness value errors when viewing exported MR Elastography (MRE) stiffness maps to viewer Picture Archiving and Communication System (PACS).
-
- Ongoing Z-2209-2025
- Ongoing Z-2208-2025
- Ongoing Z-2204-2025
The potential for component failures in the Gradient Coil of the affected MR systems may act as a heat source with a potential to produce smoke and/or fire.
-
- Ongoing Z-1795-2025
- Ongoing Z-1798-2025
- Ongoing Z-1801-2025
Potential for alignment errors in the cross reference line functionality when reviewing images generated with the MobiView application.
-
- Ongoing Z-1950-2024
- Ongoing Z-1949-2024
- Ongoing Z-1948-2024
Oil may leak from the HA FlexTrack Trolley onto the floor when pressing the hydraulic pedal, resulting in a potential slipping/falling hazard
-
- Ongoing Z-1850-2024
- Ongoing Z-1851-2024
The g-MDU (global Mains Distribution Unit) L3 terminal connection may become loose creating a hotspot that may cause smoke/fire to alarm in the hospital's technical room, resulting in Smoke and/or fire
-
- Ongoing Z-1571-2024
- Ongoing Z-1569-2024
- Ongoing Z-1570-2024
- Ongoing Z-1568-2024
Patient support table floor plate may be incorrectly installed.
-
- Ongoing Z-2397-2023
The system operator is able to bypass the SmokeDetector Interlock system locking mechanism after a smoke detection by power cycling the system.
-
- Ongoing Z-2400-2023
During installation of the SmokeDetector Interlock, a connecting cable, between the SmokeDetector Interlock and the host PC, may not have been properly installed. This connection is used for service diagnostics and does not impact the functionality of the system and/or the SmokeDetector Interlock system.
-
- Ongoing Z-0715-2024
The sealed magnet will experience uncontrolled shutdown known as Loss-of-Field (LoF) if the magnet loses cryo-cooling (e.g. caused by a power outage on site.)
Specification
- Trade Name
- HA FlexTrak EUDAMEDIngenia GUDID
- Generic Name
- Full-body MRI system, superconducting magnet
- Device Name
- Trolley, Acoustic Hood and Tabletop extender
- Model / Ref / Catalog
- 989710006412, HA FlexTrak
- Primary DI / UDI-DI
- 00884838099470
- Basic UDI-DI
- 0884838BM474TB
- Direct Marketing DI
- 00884838099470
- FDA Product Code
- LNH
- EMDN Code
- Z1105018099 Magnetic resonance (mr) systems - hardware accessories - other
- GMDN Term
- Full-body MRI system, superconducting magnet
- Device Class
- Class I EUDAMEDClass II GUDID
- Regulation Number
- 892.1000
- Market of Registration
- Netherlands
- Commercial Distribution
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / Reference | 989710006412 | HA FlexTrak |
| Device Class | Class I | Class II |
Manufacturer details
- EUDAMED SRN
- NL-MF-000001489
Other devices from Philips Medical Systems Nederland B.V.
See all devices from Philips Medical Systems Nederland B.V. →
Properties & raw data
Show properties, registry sources and raw records
Other properties (22)
- Sterile: No
- Single Use: No
- Implantable: No
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- CMR Substance: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Endocrine Disruptor: No
- Administering Medicine: No
- Measuring Function: No
- Incorporates Medicinal Product: No
- Over-the-Counter: No
- Convenience Kit: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Lot / Batch Number: No
- Expiration Date: No
- Manufacturing Date: No
Sources (2)
- EUDAMED 625601a0-0ed6-4884-9f18-68766dfe79af
- FDA UDI 6455a12a-f174-4929-b8d4-8786ce85d1f1