← Back to catalogue

Had1717mc

FDA UDI

Class II (US FDA UDI)

by H&abyz Co., Ltd.

Identity

Trade Name
HAD1717MC FDA UDI
Generic Name
Indirect flat panel x-ray detector FDA UDI
Device Name
The HAD1717MC is a wired digital flat panel X-ray detector. The HAD1717MC X-ray detector consists of a TFT panel and a scintillator electronic controller, and supports AED (Automatic Exposure Detection) function that can operate without a separate trigger signal. Flat panel sensors for HAD1717MC are fabricated using thin film technology based on amorphous silicon technology, and the sensors are similar to existing photodiode arrays. In this case, each pixel is composed of a photodiode and a thin film transistor (TFT). Amorphous silicon photodiodes are optimized for green wavelengths and can be used in combination with scintillators such as CsI. The incident X-rays are converted into visible light by the scintillator, and the visible light is stored in an internal capacitor through a photodiode. Charges charged to capacitors switch TFT gates of panel matrix (panel matrix) and convert them into digital signals on a line and pass them to the control unit. The digital data generated is then passed to the PC via Ethernet. FDA UDI
Model / Reference
HAD1717MC FDA UDI
Description
The HAD1717MC is a wired digital flat panel X-ray detector. The HAD1717MC X-ray detector consists of a TFT panel and a scintillator electronic controller, and supports AED (Automatic Exposure Detection) function that can operate without a separate trigger signal. Flat panel sensors for HAD1717MC are fabricated using thin film technology based on amorphous silicon technology, and the sensors are similar to existing photodiode arrays. In this case, each pixel is composed of a photodiode and a thin film transistor (TFT). Amorphous silicon photodiodes are optimized for green wavelengths and can be used in combination with scintillators such as CsI. The incident X-rays are converted into visible light by the scintillator, and the visible light is stored in an internal capacitor through a photodiode. Charges charged to capacitors switch TFT gates of panel matrix (panel matrix) and convert them into digital signals on a line and pass them to the control unit. The digital data generated is then passed to the PC via Ethernet. FDA UDI

Identifiers

Primary DI / UDI-DI
08800070400012 FDA UDI
510(k) Number
K200018 FDA UDI
FDA Product Code
MQB FDA UDI
GMDN Term
Indirect flat panel x-ray detector FDA UDI

Classification

Device Class
Class II FDA UDI
Regulation Number
892.1680 FDA UDI
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

No

FDA UDI

Single Use

No

FDA UDI

Implantable

No

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

Yes

FDA UDI

Expiration Date

No

FDA UDI

Manufacturing Date

Yes

FDA UDI

Category: Indirect flat panel x-ray detector

Had1717mc by H&abyz Co., Ltd. — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS

Similar devices

Also classified as Indirect flat panel x-ray detector.

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Manufacturer
H&abyz Co., Ltd.

Sources (1)

  • FDA UDI f71a0ad5-c6a1-4b5c-ac5e-d5566f9da52f 35 fields · synced May 30, 2026