# HAMILTON-G5

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/hamilton-g5-cbk>
- Manufacturer: [Hamilton Medical AG](https://devicerts.com/manufacturers/hamilton-medical-ag) (Switzerland)
- Device class: Class II (US FDA)
- FDA product code: CBK

## Overview

*AI-generated summary, 2026-09-23. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Hamilton-G5 is a Ventilator, Continuous, Facility Use, classified as a device class 2. It is used in the medical specialty of Anesthesiology.

The Hamilton-G5 is supplied with various registration numbers, including 1218058, 3010017366, and others. It is regulated under the regulation number 868.5895 and has been cleared with a Traditional clearance type, with a decision code of SESE, indicating it is substantially equivalent. The device has an FDA 510K authorization.

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K131774 · decision 2013-10-09 · decision SESE · status: Active

## Recalls

- Z-1874-2019 · Class I · terminated · initiated 2019-03-25: New software version for affected ventilators reduces the probability of the ventilator entering an ambient state, in which the inspiratory channel and expiratory valves are opened, letting the patient breathe room air unassisted. When the ventilator enters the ambient state, alternative ventilation must be provided immediately.
- Z-1624-2016 · Class II · terminated · initiated 2016-03-09: After performing the suctioning maneuver, including disconnecting the patient, suctioning , and reconnecting the patient, the preset pattern of ventilation many not continue as expected.
- Z-2057-2015 · Class II · terminated · initiated 2015-03-24: Customer reports that the ventilator display can freeze. Ventilation continues but the information is no longer displayed on the screen and the user can no longer operate the device.
- Z-0151-2016 · Class I · terminated · initiated 2014-04-22: Ventilation and alarms of a HAMILTON-G5 ventilator can be suppressed unintentionally after the activation of a suctioning maneuver by the operator; this situation can occur regardless of the selected patient group (neonatal, pediatric and adult).

## Identifiers

- 510(k) Number: K131774 [FDA 510(k)]
- FDA product code: CBK [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 868.5895 [FDA 510(k)]
- Advisory committee: Anesthesiology [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: HAMILTON-G5, Hamilton Medical AG. deviCERTS medical device catalogue. https://devicerts.com/devices/hamilton-g5-cbk (data as of 2026-11-17).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-17
- JSON: <https://devicerts.com/devices/hamilton-g5-cbk.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/hamilton-g5-cbk
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.
