Harmony™ HARMONY-DCS
Ref HARMONY-DCS
Harmony™ HARMONY-DCS is a device classified as Class III (EU), Unclassified (US) made by Medtronic, Inc., registered in EUDAMED on 20 May 2026 (Basic UDI-DI 0763000B00010977W) with CE/MDR certificate 2266041TD02 valid until 1 Dec 2029, approved under FDA PMA P200046 on 26 Mar 2021 and listed in FDA GUDID since 22 Apr 2021 (UDI-DI 00763000582951), active as of 23 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
1 Dec 2029
FDA recalls
2 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number2266041TD02 | Date4 Jun 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00763000582951 | Date22 Apr 2021 | StatusListed |
| United States | FDA PMAAPPR GUDID | NumberP200046 | Date26 Mar 2021 | StatusActive |
Official records
- EUDAMED public site 0763000B00010977W
- AccessGUDID record 00763000341367
- FDA PMA database P200046
Across registries
- EUDAMED Basic UDI-DI 0763000B00010977W registered 20 May 2026 Active
- FDA PMA P200046 decided 26 Mar 2021 Active
- FDA GUDID UDI-DI 00763000582951 listed 22 Apr 2021 Listed
Certificates
- 2266041TD02 Active
Technical documentation EU MDR
- Certifier
- DEKRA Certification B.V. 0344
- Issued
- 4 Jun 2026
- Expires
- 1 Dec 2029
- Reason
- Change approved
Recalls
-
- Ongoing Z-2624-2026
Devices containing inner shaft assemblies from specific manufacturing lots may have an increased potential for distal tip detachment from the delivery system under certain procedural or anatomical conditions due to a manufacturing issue.
-
- Ongoing Z-0927-2022
There is potential for the capsule bond to break during the procedure.
Timeline
- Approved FDA PMA P200046
- Listed FDA GUDID 00763000582951
- Recall initiated FDA recalls Z-0927-2022
- Registered EUDAMED 0763000B00010977W
- Recall initiated FDA recalls Z-2624-2026
- Certificate issued EUDAMED 2266041TD02
- Certificate expires EUDAMED 2266041TD02
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Harmony™
- Generic name
- Pulmonary transcatheter heart valve bioprosthesis
- Model / reference
- HARMONY-DCS
- Primary DI / UDI-DI
- 00763000582951 EUDAMED00763000341367 GUDID
- Basic UDI-DI
- 0763000B00010977W
- PMA number
- FDA product code
- NPV
- EMDN code
- P07038002 Cardiac valve transcatheter implant accessories
- GMDN term
- Pulmonary transcatheter heart valve bioprosthesis
- Device class
- Class III EUDAMEDUnclassified GUDID
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Size
- Length — 101.0 CentimeterOuter Diameter — 8.33 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Primary DI / UDI-DI | 00763000582951 | 00763000341367 |
| Device class | Class III | Unclassified |
| Implantable | No | Yes |
Similar devices in this category
Other devices filed under CARDIAC VALVE TRANSCATHETER IMPLANT ACCESSORIES.
- FlexNav™ FNAV-DS-SM by ST. JUDE MEDICAL, INC.
- FlexNav™ FNAV-DS-LG by ST. JUDE MEDICAL, INC.
- SAI Delivery Catheter 631102-2 by HighLife
- Edwards Commander M Delivery system 9880CM29CE by Edwards Lifesciences LLC
- Trilogy Sheath/Dilator TRILOGY-INT by JenaValve Technology, Inc.
- Trilogy Delivery Catheter TRILOGY-DC-M by JenaValve Technology, Inc.
- LuX Valve Plus JS/TTVDJ-33 by Jenscare Scientific (Netherlands) B.V.
- Edwards EVOQUE 9850TDS by Edwards Lifesciences LLC
- IMPERIA-S Delivery System DSL-AO18G2115S by NVT GmbH
- Transseptal Delivery Catheter 631109-LC by HighLife