Head Fixation Device HFD100
by IMRIS Imaging, Inc. 2 variants
Head Fixation Device HFD100 is a Class II device made by IMRIS Imaging, Inc., cleared under FDA 510(k) K103493 on 11 Mar 2011 and listed in FDA GUDID since 28 Feb 2017 (UDI-DI 00857534006394), active as of 22 Oct 2026. 3 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00857534006394 | Date28 Feb 2017 | StatusListed |
| United States | FDA 510(k)SESE | NumberK103493 | Date11 Mar 2011 | StatusActive |
Official records
- AccessGUDID record 00857534006394
- FDA 510(k) database K103493
Across registries
- FDA 510(k) K103493 decided 11 Mar 2011 Active
- FDA GUDID UDI-DI 00857534006394 listed 28 Feb 2017 Listed
Recalls
-
- Ongoing Z-1034-2026
Torque screw may crack or separate. If used, an affected screw could lead to inadequate head stabilization, compromised surgical precision, procedural delays, requirement for alternate head fixation methods, and risk of patient injury.
-
- Terminated Z-0934-2022
Reports have been received that after normal or routine lateral forces are applied to the head fixation device, the split block clamp may deflect (rotationally around the axis) and not return to within acceptable distance from its prior position after the force is removed. In order to reduce deflection at the table mount location, users have tightened the hand knob screw to a degree that it is then difficult to untighten it later in the clinical workflow. Rotational movement at the table attachment point could result in HFD movement going unnoticed, which could result in a situation where surgical or medical intervention is necessary, a situation where navigation needs to be reestablished, or a situation resulting in extended time under anesthesia for the patient. It may also be difficult to loosen the mount clamp component after use, potentially leading to ergonomic injury or a workaround during equipment teardown.
-
- Terminated Z-3211-2017
incorrect thread on thumbscrews
Timeline
- Cleared FDA 510(k) K103493
- Listed FDA GUDID 00857534006394
- Recall initiated FDA recalls Z-3211-2017
- Recall initiated FDA recalls Z-0934-2022
- Recall initiated FDA recalls Z-1034-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Generic name
- Skull clamp
- Model / reference
- HFD100
- Description
- Head Fixation Device HFD100 , 113803-600
- Primary DI / UDI-DI
- 00857534006394
- 510(k) Number
- FDA product code
- HBL
- GMDN term
- Skull clamp
- Device class
- Class II
- Regulation number
- 882.4460
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional