Head Frame Kit
by Varian Medical Systems, Inc.
Part of a family of 6 devices: see the family page
Ref P1006823005
Head Frame Kit (P1006823005) is a stereotactic radiosurgical invasive head frame (EU MDR Class IIa; FDA Class II; FDA product code IYE, Accelerator, linear, medical) made by Varian Medical Systems, Inc., registered in EUDAMED on 30 May 2025 (Basic UDI-DI 089947500200111PD), cleared under FDA 510(k) K180586 on 2 Apr 2018 (1 earlier submission) and listed in FDA GUDID since 27 Oct 2021 (UDI-DI 00858086006634), active as of 8 Nov 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number089947500200111PD 00858086006634 | Date30 May 2025 | StatusActive |
| United States | GUDID listing GUDID | Number00858086006634 | Date27 Oct 2021 | StatusListed |
| United States | FDA 510(k) 510(k) | NumberK180586 | Date2 Apr 2018 | StatusActive |
Official records
- EUDAMED public site 089947500200111PD
- AccessGUDID record 00858086006634
- FDA 510(k) database K180586
- FDA 510(k) database K142560
From the FDA record
- MRI safety
- MR Unsafe
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI 089947500200111PD registered 30 May 2025 Active
- FDA 510(k) K180586 decided 2 Apr 2018 Active
- FDA GUDID UDI-DI 00858086006634 listed 27 Oct 2021 Listed
Recalls
-
- Terminated Z-0077-2017
Varian Medical Systems has received a report that a user was able to easily rotate the head frame posts when attached to the mounting cam on the metal head ring. There was no report of serious injury due to this issue
Timeline
- Cleared FDA 510(k) K142560
- Recall initiated FDA recalls Z-0077-2017
- Cleared FDA 510(k) K180586
- Listed FDA GUDID 00858086006634
- Registered EUDAMED 089947500200111PD
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- United States
- European Union
Specification
- Generic name
- Stereotactic radiosurgical invasive head frame
- Device name
- HeadFrame
- Model / reference
- P1006823005
- Primary DI / UDI-DI
- 00858086006634
- Basic UDI-DI
- 089947500200111PD
- 510(k) Number
- FDA product code
- IYE
- EMDN code
- Z11010780 Radiosurgery instruments - hardware accessories
- GMDN term
- Stereotactic radiosurgical invasive head frame
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.5050
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
- MRI safety
- MR Unsafe
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Manufacturer details
- EUDAMED SRN
- US-MF-000001784
- Authorised representative
- Siemens Healthineers Nederland B.V. NL-AR-000000803
Similar devices in this category
Other devices filed under RADIOTHERAPY AND RADIOSURGERY INSTRUMENTS.
- Leksell GammaPlan 1567714 by Elekta Solutions AB
- ZAP-X Radiosurgery System by Zap Surgical Systems, Inc.
- Leksell GammaPlan 11.5 1577756 by ELEKTA SOLUTIONS AB
- EDGE Detector (BNC) 11180000Z by Sun Nuclear Corporation
- MOBETRON by Intraop Medical, Inc.
- Medical Linear Accelerator System Class llb by Shanghai United Imaging Healthcare Co., Ltd.
- Orfit Industries 29111-G by Orfit Industries NV
- Orfit Industries 29111-P by Orfit Industries NV
- Standard Imaging DoseView 3D 92260 by STANDARD IMAGING INC.
- Standard Imaging DoseView 1D 70800 by STANDARD IMAGING INC.