Skip to content

Head Frame Kit

by Varian Medical Systems, Inc.

Part of a family of 6 devices: see the family page

Ref P1006823005

Head Frame Kit (P1006823005) is a stereotactic radiosurgical invasive head frame (EU MDR Class IIa; FDA Class II; FDA product code IYE, Accelerator, linear, medical) made by Varian Medical Systems, Inc., registered in EUDAMED on 30 May 2025 (Basic UDI-DI 089947500200111PD), cleared under FDA 510(k) K180586 on 2 Apr 2018 (1 earlier submission) and listed in FDA GUDID since 27 Oct 2021 (UDI-DI 00858086006634), active as of 8 Nov 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

1 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, FDA 510(k), GUDID, synced 8 Nov 2026.

Regulatory status

as of registry sync 8 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number089947500200111PD Basic UDI-DI 00858086006634UDI-DIDate30 May 2025RegisteredStatusActive
United StatesGUDID listing GUDID Number00858086006634 UDI-DI Date27 Oct 2021ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k) 510(k) NumberK180586 Date2 Apr 2018IssuedStatusActive

Official records

From the FDA record

MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 089947500200111PD registered 30 May 2025 Active
  • FDA 510(k) K180586 decided 2 Apr 2018 Active· +1 more in the status table
  • FDA GUDID UDI-DI 00858086006634 listed 27 Oct 2021 Listed

Recalls

1 recall · FDA

    • Terminated Z-0077-2017 FDA Class II initiated 13 Sep 2016

    Varian Medical Systems has received a report that a user was able to easily rotate the head frame posts when attached to the mounting cam on the metal head ring. There was no report of serious injury due to this issue

Timeline

5 dated events

  1. Cleared FDA 510(k) K142560
  2. Recall initiated FDA recalls Z-0077-2017
  3. Cleared FDA 510(k) K180586
  4. Listed FDA GUDID 00858086006634
  5. Registered EUDAMED 089947500200111PD

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • United States FDA 510(k) Active
  • European Union CE/MDR Active

Specification

EUDAMED · 510(k) · GUDID

Generic name
Stereotactic radiosurgical invasive head frame
Device name
HeadFrame
Model / reference
P1006823005
Primary DI / UDI-DI
00858086006634
Basic UDI-DI
089947500200111PD
510(k) Number
FDA product code
IYE
EMDN code
Z11010780 Radiosurgery instruments - hardware accessories
GMDN term
Stereotactic radiosurgical invasive head frame
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.5050
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
MRI safety
MR Unsafe

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
US-MF-000001784
Authorised representative
Siemens Healthineers Nederland B.V. NL-AR-000000803

Similar devices in this category

Other devices filed under RADIOTHERAPY AND RADIOSURGERY INSTRUMENTS.

Other devices from Varian Medical Systems, Inc.

See all devices from Varian Medical Systems, Inc. →

Properties

  • Sterilise before use
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)