# Head Frame Kit

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/head-frame-kit-p1006823005>
- Manufacturer: [Varian Medical Systems, Inc.](https://devicerts.com/manufacturers/varian-medical-systems-inc) (United States)
- Device class: Class IIa (EU MDR); Class II (US FDA)
- FDA product code: IYE
- EMDN: Z11010780 RADIOSURGERY INSTRUMENTS - HARDWARE ACCESSORIES
- GMDN: Stereotactic radiosurgical invasive head frame (35361)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 089947500200111PD · UDI-DI 00858086006634 · registered 2025-05-30 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 00858086006634 · listed 2021-10-27 · status: Listed (GUDID: in commercial distribution)
- **510(k)** · FDA 510(k) · United States · K180586 · issued 2018-04-02 · status: Active
- **510(k)** · FDA 510(k) · United States · K142560 · issued 2014-12-11 · status: Active

## Recalls

- Z-0077-2017 · Class II · terminated · initiated 2016-09-13: Varian Medical Systems has received a report that a user was able to easily rotate the head frame posts when attached to the mounting cam on the metal head ring. There was no report of serious injury due to this issue

## Identity

- Generic name: Stereotactic radiosurgical invasive head frame [FDA GUDID (AccessGUDID)]
- Device name: HeadFrame [EUDAMED]
- Model / reference: P1006823005 [EUDAMED, FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00858086006634 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 089947500200111PD [EUDAMED]
- 510(k) Number: K180586 [FDA GUDID (AccessGUDID)]
- FDA product code: IYE [FDA GUDID (AccessGUDID)]
- EMDN code: Z11010780 [EUDAMED]
- GMDN term: Stereotactic radiosurgical invasive head frame (35361) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class IIa [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 892.5050 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Netherlands [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Clinical & Handling

- Sterilisation method: Moist Heat or Steam Sterilization [FDA GUDID (AccessGUDID)]
- MRI safety: MR Unsafe [FDA GUDID (AccessGUDID)]

## Properties

- Sterilise before use: Yes [EUDAMED, FDA GUDID (AccessGUDID)]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Manufacturing date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Prescription use: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Head Frame Kit, Varian Medical Systems, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/head-frame-kit-p1006823005 (data as of 2026-11-24).
- Data sources: [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-11-08
- Statuses computed as of: 2026-11-24
- JSON: <https://devicerts.com/devices/head-frame-kit-p1006823005.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/head-frame-kit-p1006823005
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.