HeartMate 3™ 10005872
HeartMate 3™ 10005872 is a Class III device made by Thoratec Corporation, approved under FDA PMA P160054 on 23 Aug 2017 and listed in FDA GUDID since 14 Jun 2022 (UDI-DI 05415067038760), active as of 23 Oct 2026. 18 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
14 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number05415067038760 | Date14 Jun 2022 | StatusListed |
| United States | FDA PMAAPPR | NumberP160054 | Date23 Aug 2017 | StatusActive |
Official records
- AccessGUDID record 05415067038760
- FDA PMA database P160054
Across registries
- FDA PMA P160054 decided 23 Aug 2017 Active
- FDA GUDID UDI-DI 05415067038760 listed 14 Jun 2022 Listed
Recalls
-
- Ongoing Z-2519-2026
- Ongoing Z-2518-2026
- Ongoing Z-2520-2026
Due to 11 volt Backup Battery failures.
-
- Ongoing Z-0506-2026
- Ongoing Z-0505-2026
Due to potential corrosion issues associated with the Backup Battery cable connector that may cause a Backup Battery Fault Alarm.
-
- Ongoing Z-2290-2025
- Ongoing Z-2291-2025
Due to misaligned V-Lock feature on the Mobile Power Unit power cords, which prevents the locking mechanism from properly engaging with the Mobile Power Unit and may cause unintended disconnect.
-
- Ongoing Z-1570-2025
Left Ventricular Assist System Mobile Power Unit (MPU) may have electrical component that may cause MPU not to turn on, unprompted shut down, or turning off/restarting, may cause system controller to indicate Yellow Wrench or No External Power alarms. If MPU losses power, System Controller can support the pump up to 15 minutes, and if not switched to rechargeable batteries, pump may lose power.
-
- Ongoing Z-2583-2024
Left ventricular assist system controller UI membrane/screen may lift along the edge of the controller housing, and if controller is exposed to fluid, ingress may occur, which may damage printed circuit board assemblies, which could result in unexpected and false positive alarms, loss of visual alarms, loss of user interface(use of buttons, loss of visual alarms,etc.), loss of power, and pump stop
-
- Ongoing Z-1921-2024
System monitor screen may display atypical behavior: Overlapping screens/buttons, Frozen screen, Distorted text, blanks, or zeroes in place of values, Unresponsive buttons where the user is unable to initiate a command, which may lead to anxiety /inconvenience, hemodynamic compromise, extended surgical time, and Pump Stop command may be selected
-
- Ongoing Z-1693-2024
- Ongoing Z-1692-2024
Potential for a leak path at the seal interface between the left ventricle assist system inflow cannula and the titanium apical cuff.
-
- Ongoing Z-1301-2024
Observed outflow graft deformation known as Extrinsic Outflow Graft Obstruction (EOGO) associated with Left Ventricular Assist System.
-
- Ongoing Z-0842-2024
Due to software and controller systems that results in unexpected pump start or pump stop.
-
- Terminated Z-0746-2020
Excessive static electricity can potentially cause unrecoverable power loss and damage to the mobile power unit that can be used to power the left ventricular assist system, which could lead to no or reduced blood flow from the left ventricular assist system.
-
- Terminated Z-2349-2019
- Terminated Z-2348-2019
Outflow Graft leaking at the pump connection during the implantation process. If the C-Ring is insufficiently seated, it renders the device nonfunctional because the Outflow Graft connection will leak during the implant procedure.
-
- Terminated Z-1774-2018
Reports of outflow graft twist occlusions. Patients whose devices experience outflow graft occlusions will experience a persistent low flow alarm. Outflow graft occlusions can result in serious adverse events such as hemodynamic compromise, thrombus, and death.
Timeline
- Recall initiated FDA recalls Z-1921-2024
- Recall initiated FDA recalls Z-2583-2024
- Recall initiated FDA recalls Z-1570-2025
- Recall initiated FDA recalls Z-2290-2025
- Recall initiated FDA recalls Z-2291-2025
- Recall initiated FDA recalls Z-0506-2026
- Recall initiated FDA recalls Z-0505-2026
- Recall initiated FDA recalls Z-2519-2026
- Recall initiated FDA recalls Z-2518-2026
- Recall initiated FDA recalls Z-2520-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA PMA Active
Specification
- Trade name
- HeartMate 3™
- Generic name
- Cardiothoracic surgical procedure kit, non-medicated, single-use
- Model / Ref / Catalog
- 10005872
- Primary DI / UDI-DI
- 05415067038760
- PMA number
- FDA product code
- DSQ
- GMDN term
- Cardiothoracic surgical procedure kit, non-medicated, single-use
- Device class
- Class III
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code DSQ (Ventricular (assist) bypass).
- EXCOR® C23V-004m by Berlin Heart GmbH
- EXCOR® C19V-020 by Berlin Heart GmbH
- CentriMag Circulatory Support System by Abbott
- Thoratec Ventricular Assist Device (VAD) System by Thoratec Laboratories Corp.
- HeartMate 1000A IP LVAD by Thoratec Corp
- HeartMate 3 Left Ventricular Assist System by Abbott Medical
- HeartMate II Left Ventricular Assist System by Abbott Medical
- EXCOR Pediatric Ventricular Assist Device by Berlin Heart, Inc.
- Abiomed BVS 5000 Bi-Ventricular Support System by Abiomed Cardiovascular, Inc.
- NOVACOR LVAS by Worldheart, Inc.