Skip to content

Hemacarotid Patch HEK08/75CP (1)

by Intervascular, Inc.

Ref HEK08/75CP (1)

Hemacarotid Patch HEK08/75CP (1) is a cardiovascular patch (EU MDD Class III; FDA Class II; FDA product code DSY, Prosthesis, Vascular Graft, Of 6mm And Greater Diameter) made by Intervascular, Inc., registered in EUDAMED on 23 Jul 2026 (Basic UDI-DI B-00384401001416), cleared under FDA 510(k) K964625 on 5 May 1997 and listed in FDA GUDID since 24 Sep 2015 (UDI-DI 00384401001416), active as of 24 Oct 2026. 2 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

2 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K964625

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00384401001416 Basic UDI-DI 00384401001416UDI-DIDate23 Jul 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00384401001416 UDI-DI Date24 Sep 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)ST GUDID from GUDID Traditional NumberK964625 Date5 May 1997DecidedStatusActive

Official records

From the FDA record

Device description
Hemacarotidpatch Knitted Collagen Coated Vascular Patch
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 24 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00384401001416 registered 23 Jul 2026 Active
  • FDA 510(k) K964625 decided 5 May 1997 Active
  • FDA GUDID UDI-DI 00384401001416 listed 24 Sep 2015 Listed

Recalls

2 recalls · FDA

    • Terminated Z-1439-2010 FDA Unclassified (pre-2012) initiated 9 Dec 2009

    The external lid of Intervascular's prosthesis has a cut in it which may compromise package integrity and therefore sterility.

    • Terminated Z-1427-2010 FDA Unclassified (pre-2012) initiated 9 Dec 2009

    Packaging was mislabeled.

Timeline

5 dated events

  1. Cleared FDA 510(k) K964625
  2. Recall initiated FDA recalls Z-1439-2010
  3. Recall initiated FDA recalls Z-1427-2010
  4. Listed FDA GUDID 00384401001416
  5. Registered EUDAMED B-00384401001416

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Hemacarotid Patch Knitted EUDAMED
Hemacarotid Patch GUDID
Generic name
Cardiovascular patch, animal-derived
Model / Ref / Catalog
HEK08/75CP (1)
Primary DI / UDI-DI
00384401001416
Basic UDI-DI
B-00384401001416
510(k) Number
FDA product code
DSY
EMDN code
P07020201 Dacron vascular patches
GMDN term
Cardiovascular patch, animal-derived
Device class
Class III EUDAMED
Class II GUDID
Regulation number
870.3450
EU registration type
Legacy device (under a directive)
EU market of registration
France
GUDID distribution status
In Commercial Distribution
Size
Length — 75 Millimeter
Width — 8 Millimeter

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class III
GUDID
Class II

Device class is stated on each registry's own scale: Class III in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under VASCULAR PATCHES.

Other devices from Intervascular, Inc.

See all devices from Intervascular, Inc. →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Contains animal tissues or cells
  • Prescription use
  • Lot / batch number
  • Serial number
  • Expiration date
  • Manufacturing date
Other properties (16, all answered No)