Skip to content

Hemashield M002020955890

by Intervascular, Inc.

Ref M002020955890

Hemashield M002020955890 is a synthetic vascular graft (EU MDD Class III; FDA Class II; FDA product code MAL, Graft, Vascular, Synthetic/Biologic Composite) made by Intervascular, Inc., registered in EUDAMED on 24 Jul 2026 (Basic UDI-DI B-00384401017820), cleared under FDA 510(k) K954848 on 1 Feb 1996 and listed in FDA GUDID since 12 Nov 2015 (UDI-DI 00384401017820), active as of 25 Oct 2026. 6 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

6 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K954848

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 25 Oct 2026.

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00384401017820 Basic UDI-DI 00384401017820UDI-DIDate24 Jul 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00384401017820 UDI-DI Date12 Nov 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)ST GUDID from GUDID Traditional NumberK954848 Date1 Feb 1996DecidedStatusActive

Official records

From the FDA record

Device description
Hemashield Gold Knitted Microvel AxilloBifemoral Double Velour Vascular Graft with Graft Sizer Accessory
MRI safety
MR Safe
Natural rubber latex
Labelled as not made with natural rubber latex
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 25 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00384401017820 registered 24 Jul 2026 Active
  • FDA 510(k) K954848 decided 1 Feb 1996 Active
  • FDA GUDID UDI-DI 00384401017820 listed 12 Nov 2015 Listed

Recalls

6 recalls · FDA

    • Terminated Z-0729-2022 FDA Class II initiated 14 Jan 2022

    Outer labelling (HEMASHIELD GOLD Knitted Microvel Double Velour Bifurcated Vascular Graft, D: 16 x 8 mm; L: 40 cm) does not correspond to the (inner) sterile packaging labelling (HEMASHIELD GOLD Knitted Microvel Double Velour Straight Vascular Graft, D: 7 mm L: 60 cm). Mislabeled product could cause a disruption of the vascular anastomosis in the long term, creating a pseudo-aneurysm

    • Terminated Z-0403-2022 FDA Class II initiated 1 Dec 2021

    There is a probable mislabeling of product. A Hemashield Platinum Woven Double Velour Bifurcated Vasuclar Graft, SN 1259735369, 24 mm x 12 mm, REF Number M00202166241P0 is likely packaged inside of the carton instead of a Hemashield Gold Knitted Microvel Double Velour Bifurcated Vascular Graft; SN 1260004700; 18 mm x 9 mm; REF Number M002020851890 or a Hemashield Gold Knitted Microvel Double Velour Bifurcated Vascular Graft; SN 1259882880; 18 mm x 9 mm; Ref Number M002020851890.

  • 3 recalls, same reason

    • Terminated Z-1859-2020 FDA Class II initiated 7 Apr 2020
    • Terminated Z-1861-2020 FDA Class II initiated 7 Apr 2020
    • Terminated Z-1860-2020 FDA Class II initiated 7 Apr 2020

    Potential small holes at the seam lines of Hemashield branches causing intra-operative bleeding at the seam lines of the branches of Hemashield grafts

    • Terminated Z-2066-2010 FDA Unclassified (pre-2012) initiated 24 May 2010

    Various Hemashield products may develop glycerol droplets on the inner blister of the package if not stored under proper conditions, which could lead to the prolongation of surgery and potentially compromise patient safety.

Timeline

9 dated events

  1. Cleared FDA 510(k) K954848
  2. Recall initiated FDA recalls Z-2066-2010
  3. Listed FDA GUDID 00384401017820
  4. Recall initiated FDA recalls Z-1859-2020
  5. Recall initiated FDA recalls Z-1861-2020
  6. Recall initiated FDA recalls Z-1860-2020
  7. Recall initiated FDA recalls Z-0403-2022
  8. Recall initiated FDA recalls Z-0729-2022
  9. Registered EUDAMED B-00384401017820

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
HEMASHIELD GOLD Knitted MICROVEL Double Velour Vascular Grafts EUDAMED
Hemashield GUDID
Generic name
Synthetic vascular graft, non-medicated
Model / Ref / Catalog
M002020955890
Primary DI / UDI-DI
00384401017820
Basic UDI-DI
B-00384401017820
510(k) Number
FDA product code
MAL
EMDN code
P070102010201 Dacron vascular prostheses, multifurcated (aortic arch (also collateral and multiple) and thoracic-abdominal)
GMDN term
Synthetic vascular graft, non-medicated
Device class
Class III EUDAMED
Class II GUDID
Regulation number
870.3450
EU registration type
Legacy device (under a directive)
EU market of registration
France
GUDID distribution status
In Commercial Distribution
MRI safety
MR Safe
Size
Length — 60 Centimeter
Lumen/Inner Diameter — 8 Millimeter
Length — 100 Centimeter

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class III
GUDID
Class II

Device class is stated on each registry's own scale: Class III in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under DACRON VASCULAR PROSTHESES, MULTIFURCATED (AORTIC ARCH (ALSO COLLATERAL AND MULTIPLE) AND THORACIC-ABDOMINAL).

Other devices from Intervascular, Inc.

See all devices from Intervascular, Inc. →

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Contains animal tissues or cells
  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Serial number
  • Expiration date
  • Manufacturing date
Other properties (15, all answered No)