Skip to content

Hemashield Vantage Vascular Graft

by Meadox Medicals, Div. Boston Scientific Corp.

510(k) K961847

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)ST Traditional NumberK961847 Date22 Jan 1997DecidedStatusActive

Recalls

1 recall · FDA

    • Terminated Z-1459-05 FDA Unclassified (pre-2012) initiated 27 Jun 2005

    During surgery, several reports of the grafts fraying and tearing upon suturing by the surgeon.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DSY
Device Class
Class II
Regulation
21 CFR Part 870.3450
Advisory Committee
Cardiovascular
FDA Decision
ST

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Hemashield Vantage Vascular Graft is a synthetic prosthesis designed for systemic vascular reconstructions. It is classified as a vascular graft of 6 mm and greater diameter, intended for use in peripheral vascular applications, such as replacement in cases of aneurysmal or occlusive disease.

This device is supplied sterile and is intended for single-use. It is regulated under FDA 510(k) clearance (K961847) as a Class II medical device under regulation number 870.3450, with a substantial equivalence determination to predicate devices. Multiple registration numbers (e.g., 1721676, 1018233) correspond to its various sizes and configurations, all of which are tracked for post-market surveillance.

Other devices from Meadox Medicals, Div. Boston Scientific Corp.

See all devices from Meadox Medicals, Div. Boston Scientific Corp. →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What types of vascular procedures is the Hemashield Vantage Vascular Graft specifically designed for?

    The Hemashield Vantage Vascular Graft is designed for systemic vascular reconstructions, particularly in peripheral vascular applications. It is intended for use in replacing diseased sections of blood vessels, such as those affected by aneurysmal or occlusive disease, where a graft with a diameter of 6 mm or greater is required.

  • Is the Hemashield Vantage Vascular Graft intended for reuse, or is it meant to be used only once?

    The Hemashield Vantage Vascular Graft is explicitly intended for single-use only, as stated in its design and regulatory documentation. This ensures patient safety and sterility standards are maintained.

  • How is the Hemashield Vantage Vascular Graft supplied, and what does this mean for handling?

    The Hemashield Vantage Vascular Graft is supplied sterile, meaning it is pre-sterilized and packaged to prevent contamination before use. This allows for immediate use upon opening, provided proper sterile technique is followed during handling and implantation.

  • What regulatory pathway was followed for the approval of the Hemashield Vantage Vascular Graft?

    The Hemashield Vantage Vascular Graft received FDA clearance through a 510(k) submission, specifically under the traditional review pathway. It was determined to be substantially equivalent to predicate devices and falls under FDA regulation number 870.3450, classified as a Class II medical device. The device is also tracked for post-market surveillance.

  • Are there multiple sizes or configurations available for the Hemashield Vantage Vascular Graft, and how are they tracked?

    Yes, the Hemashield Vantage Vascular Graft comes in multiple sizes and configurations, each with its own registration number (e.g., 1721676, 1018233, etc.). These variations are tracked individually under the FDA’s post-market surveillance system to ensure ongoing safety and performance monitoring.