HemosIL CL HIT-IgG(PF4-H)
by Instrumentation Laboratory (IL) Co.
510(k) K243374Ref 0029706200
Active
Valid until
Not listed
FDA recalls
None foundTrust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/IVDR EUDAMED | Number0195226001204PZ 00195226001204 | Date25 May 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00195226001204 | Date30 Oct 2025 | StatusListed |
| United States | FDA 510(k)SESE 510(k) | NumberK243374 | Date28 Jan 2025 | StatusActive |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
No FDA recalls found in the data synced 23 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic Name
- Platelet factor 4 IVD, kit, enzyme immunoassay (EIA)
- Model / Ref / Catalog
- 0029706200, 00029706200
- Primary DI / UDI-DI
- 00195226001204
- Basic UDI-DI
- 0195226001204PZ
- Direct Marketing DI
- 00195226001204
- 510(k) Number
- FDA Product Code
- LCO
- EMDN Code
- W0103020402 Platelet factor 4
- GMDN Term
- Platelet factor 4 IVD, kit, enzyme immunoassay (EIA)
- Device Class
- Class B EUDAMEDClass II 510(k)GUDID
- Regulation
- 21 CFR Part 864.7695
- EU market of registration
- Italy
- Advisory Committee
- Hematology
- FDA Decision
- SESE Substantially Equivalent
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | 510(k) | GUDID |
|---|---|---|---|
| Device Class | Class B | Class II | Class II |
Overview
AI-generated summary, 18 Sep 2026
The HemosIL CL HIT-IgG (PF4-H) is a Platelet Factor 4 Radioimmunoassay, a diagnostic in vitro device used to detect and quantify IgG antibodies against platelet factor 4 (PF4) in human plasma. These antibodies are associated with heparin-induced thrombocytopenia (HIT), a potentially life-threatening condition requiring rapid and accurate diagnosis. The assay provides a quantitative measurement to aid clinical decision-making in suspected HIT cases.
This device is intended for in vitro diagnostic use in clinical laboratories and is supplied as a single-use reagent kit. It is not sterile and requires reconstitution and preparation per manufacturer instructions. The assay is classified under EU IVDR and has received FDA 510(k) clearance as substantially equivalent to a predicate device. Storage and handling must comply with standard laboratory protocols for immunoassay reagents.
Other devices from Instrumentation Laboratory Company
Questions
AI-generated answers, 18 Sep 2026
What is the HemosIL CL HIT-IgG (PF4-H) used to detect and how does it help in clinical settings?
The HemosIL CL HIT-IgG (PF4-H) is a diagnostic test designed to detect and quantify IgG antibodies against platelet factor 4 (PF4) in human plasma. These antibodies are linked to heparin-induced thrombocytopenia (HIT), a serious condition that can cause dangerous blood clots. By providing a quantitative measurement, it helps clinicians confirm suspected HIT cases more accurately, enabling faster and more informed treatment decisions.
Is the HemosIL CL HIT-IgG (PF4-H) intended for single-use or repeated use, and what preparation is required?
The HemosIL CL HIT-IgG (PF4-H) is supplied as a single-use reagent kit and is not sterile. It requires reconstitution and preparation according to the manufacturer’s instructions before use, as outlined in the accompanying documentation.
How should the HemosIL CL HIT-IgG (PF4-H) be stored, and are there any special handling requirements?
Storage and handling of the HemosIL CL HIT-IgG (PF4-H) must follow standard laboratory protocols for immunoassay reagents. Since it is not sterile, it should be stored in a controlled environment to maintain its integrity until use, as specified in the manufacturer’s guidelines.
What regulatory pathways has the HemosIL CL HIT-IgG (PF4-H) followed, and what does this mean for its use?
The HemosIL CL HIT-IgG (PF4-H) has received FDA 510(k) clearance, demonstrating it is substantially equivalent to a predicate device, and it is classified under the EU’s In Vitro Diagnostic Regulation (IVDR). This means it meets regulatory standards for safety, performance, and clinical utility as an in vitro diagnostic device for detecting IgG antibodies in plasma.
Where can I find more information about the regulatory submission details for the HemosIL CL HIT-IgG (PF4-H)?
The regulatory submission for the HemosIL CL HIT-IgG (PF4-H) was filed under the product code LCO and reviewed by the FDA’s Hematology (HE) advisory committee. Additional details, including the clearance type (Traditional 510(k)), decision date (January 28, 2025), and other submission specifics, can be found in the FDA’s public database using the K-number K243374 or registration numbers listed.
Properties
Other properties (16)
- Sterile: No
- Single Use: No
- Implantable: No
- Contains Latex: No
- Microbial Substances: No
- Self Testing: No
- Near-Patient Testing: No
- Companion Diagnostics: No
- Surgical Instrument: No
- New Device: No
- Over-the-Counter: No
- Combination Product: No
- HCT/P: No
- Premarket Exempt: No
- Serial Number: No
- Manufacturing Date: No