Skip to content

HepaFat-Scan V1.1.0

by Resonance Health Analysis Services Pty, Ltd.

HepaFat-Scan V1.1.0 is a MRI system application software (FDA Class II; FDA product code LNH, System, Nuclear Magnetic Resonance Imaging) made by Resonance Health Analysis Services Pty, Ltd., cleared under FDA 510(k) K122035 on 13 Dec 2013, registered in EUDAMED and listed in FDA GUDID since 16 Jun 2023 (UDI-DI 09355529000040), active as of 23 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 23 Oct 2026

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, FDA 510(k), GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing GUDID Number09355529000040 UDI-DI Date16 Jun 2023ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k) 510(k) NumberK122035 Date13 Dec 2013IssuedStatusActive
European UnionCE/MDR EUDAMED Number— Date—StatusActive

Official records

From the FDA record

Device description
Standalone software application to facilitate the import and visualization of multi slice, gradient echo MRI data sets encompassing the abdomen, with functionality independent of the MRI equipment, to provide objective and reproducible determination of the triglyceride fat fraction in magnetic resonance images of the liver. It utilises magnetic resonance images that exploit the difference in resonance frequencies between hydrogen nuclei in water and triglyceride fat. The quantitative triglyceride fat fraction is based on the measurement of a magnetic resonance parameter that reflects the ratio of the proton density signal of triglyceride fat to the total proton density signal in the liver. HepaFat-Scan is a software device intended for quantitative measurement of the triglyceride fat fraction in magnetic resonance images of the liver. It utilises magnetic resonance images that exploit the difference in resonance frequencies between hydrogen nuclei in water and triglyceride fat. The quantitative triglyceride fat fraction is based on the measurement of a magnetic resonance parameter that reflects the ratio of the proton density signal of triglyceride fat to the total proton density signal in the liver. When interpreted by a trained physician, the results provide information that can aid in diagnosis.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • FDA 510(k) K122035 decided 13 Dec 2013 Active
  • EUDAMED Active
  • FDA GUDID UDI-DI 09355529000040 listed 16 Jun 2023 Listed

Timeline

2 dated events

  1. Cleared FDA 510(k) K122035
  2. Listed FDA GUDID 09355529000040

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • United States FDA 510(k) Active
  • European Union CE/MDR Active

Specification

EUDAMED · 510(k) · GUDID

Trade name
HepaFat-Scan
Generic name
MRI system application software
Model / reference
V1.1.0
Primary DI / UDI-DI
09355529000040
510(k) Number
FDA product code
LNH
GMDN term
MRI system application software
Device class
Class II
Regulation number
892.1000
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under MRI system application software.

Other devices from Resonance Health Analysis Services Pty, Ltd.

See all devices from Resonance Health Analysis Services Pty, Ltd. →

Properties

  • Prescription use
Other properties (14, all answered No)