Hevylite Human IgA Kappa Kit for Siemens BNII, Hevylite Human IgA Lambda Kit for Siemens BNII
510(k) K140105
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK140105 | Date18 Mar 2014 | StatusActive |
Recalls
No FDA recalls found in the data synced 6 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Full name
- Hevylite Human Iga Kappa Kit for Use on Siemens Bnii, Hevylite Human Iga Lambda Kit for Use on Siemens Bnii
- 510(k) Number
- FDA Product Code
- OPX
- Device Class
- Class II
- Regulation
- 21 CFR Part 866.5510
- Advisory Committee
- Immunology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The Hevylite Human IgA Kappa and IgA Lambda Kits are in vitro diagnostic assays designed for the quantitative measurement of immunoglobulin A (IgA) kappa and lambda free light chains in human serum. These kits are intended for use on the Siemens BNII nephelometer, enabling precise detection of IgA heavy chains combined with either kappa or lambda light chains, which aids in monitoring and diagnosing conditions such as IgA multiple myeloma.
The kits are supplied as single-use reagents for laboratory use and are intended for in vitro diagnostic applications. They are classified as FDA Class II devices with a traditional 510(k) clearance under regulation number 866.5510, specifically for immunology applications. Storage and handling follow standard in vitro diagnostic protocols, and the devices are regulated under the applicable FDA guidelines for diagnostic assays. No MRI safety considerations apply, as these are laboratory-based assays.
Other devices from The Binding Site, Ltd.
Questions
AI-generated answers, 1 Oct 2026
What conditions can the Hevylite Human IgA Kappa/Lambda Kit help diagnose or monitor?
This kit quantifies free light chains (kappa and lambda) combined with IgA heavy chains in human serum, aiding in the diagnosis and monitoring of conditions like IgA multiple myeloma. Elevated or abnormal levels of these chains can indicate plasma cell disorders, making it useful for tracking disease progression or response to treatment.
How are the Hevylite Human IgA Kappa/Lambda Kits supplied, and are they reusable?
The kits are supplied as single-use reagents designed exclusively for laboratory in vitro diagnostic use. They are not intended for reuse, as single-use assays ensure accuracy, consistency, and compliance with regulatory standards for diagnostic testing.
What nephelometer is required to use these kits, and are there compatibility concerns?
These kits are specifically designed for use on the Siemens BNII nephelometer. While they are engineered to work seamlessly with this system, compatibility should always be verified by the laboratory prior to use, particularly if software or firmware updates have been applied.
How should the Hevylite Human IgA Kappa/Lambda Kits be stored?
Storage follows standard in vitro diagnostic protocols. The kits should be stored in a clean, dry environment at room temperature (15–30°C) away from direct sunlight and extreme humidity. Always refer to the included instructions for storage details and expiration dates to maintain assay integrity.
Are there any special handling requirements for these kits, such as sterility or contamination risks?
The kits are sterile and intended for single-use in controlled laboratory settings. Proper aseptic techniques should be used during handling to prevent contamination, as with all in vitro diagnostic reagents. Avoid exposure to extreme temperatures or physical stress, which could compromise sterility or performance.