Skip to content

Hewlett Packardt Hp 85 W/ Vitatron PH1 Program Hea

by Vitatron Medical BV 510(k)

Active United States

510(k) K844484

Overview

This device is a Programmer, Pacemaker (FDA product code KRG), designed to program and configure implantable pacemakers. It facilitates adjustments to pacing parameters, such as heart rate, output, and timing, to optimize cardiac rhythm management in patients with bradycardia or other conduction disorders.

The HP-85 with Vitatron PH1 Programmer is a reusable medical device intended for use in clinical settings, including hospitals and cardiac electrophysiology labs. It received FDA 510(k) clearance under the Substantially Equivalent (SESE) designation in 1985, classified as a Class III device under regulation 870.3700. No sterility or MRI safety information is specified in the available data.

AI-generated from registry data, 18 Sep 2026.Not verified by deviCERTS or the manufacturer

Regulatory status

as of 27 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK844484 Date24 Jul 1985ClearedStatusActive

Coverage

1 jurisdiction

United States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not known
  • Not covered

United States — FDA 510(k) Active

Recalls

0 recalls · FDA

No FDA recalls on record, checked 22 Oct 2026.

Specification

510(k)

510(k) Number
FDA Product Code
KRG
Device Class
Class III
Regulation
21 CFR Part 870.3700
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Other devices from Vitatron Medical BV

See all devices from Vitatron Medical BV →

Questions

  • What clinical settings is this device intended for and how is it used there?

    This device, the Hewlett Packard HP-85 with Vitatron PH1 Programmer, is designed for use in clinical settings like hospitals and cardiac electrophysiology labs. It is a reusable programmer specifically for implantable pacemakers, allowing clinicians to adjust pacing parameters such as heart rate, output, and timing. These adjustments help optimize cardiac rhythm management in patients with bradycardia or conduction disorders, ensuring proper pacemaker function during diagnostic or therapeutic procedures.

  • Is this device single-use or reusable, and what does that mean for maintenance and upkeep?

    This device is explicitly labeled as reusable, meaning it is intended for repeated use in clinical environments. Since it is not sterile and no MRI safety information is provided, it must be cleaned, maintained, and calibrated according to manufacturer guidelines between uses. Reusability implies the need for a robust infection control protocol and regular servicing to ensure reliable performance and patient safety.

  • How was this device’s regulatory pathway determined, and what does that mean for its use today?

    The HP-85 with Vitatron PH1 Programmer received FDA 510(k) clearance under the Substantially Equivalent (SESE) designation in 1985, classified as a Class III device. This means it was deemed comparable to a legally marketed device at the time, requiring a traditional review process by the FDA’s Cardiovascular (CV) advisory committee. While the device is no longer actively cleared for new submissions, it remains compliant for use as long as it adheres to its original specifications and maintenance protocols, assuming no modifications have been made.

  • What types of pacemakers can this programmer be used with, and are there any compatibility concerns?

    This device is designed to program and configure *implantable pacemakers* broadly, though the exact models or brands compatible are not specified in the data. Since it is an older device cleared in 1985, compatibility may depend on whether the pacemaker’s programming interface aligns with the HP-85’s capabilities. Clinicians should verify compatibility with the specific pacemaker model in use, as modern pacemakers may require updated or specialized programmers. Always refer to the manufacturer’s instructions for the pacemaker and programmer to avoid mismatches.

  • What storage requirements should be considered for this device, given its reusable nature?

    While no explicit storage conditions are detailed in the data, as a reusable medical device, the HP-85 with Vitatron PH1 Programmer should be stored in a clean, dry environment protected from physical damage, extreme temperatures, and direct sunlight. Since it is not sterile, it should not be stored in a sterile field or with sterile supplies. Proper handling and maintenance protocols should be followed to prevent contamination or degradation of its components, ensuring it remains functional for repeated clinical use.