HiChem Glucose/HK Reagent Kit
510(k) K960084
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK960084 | Date4 Apr 1996 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- CFR
- Device Class
- Class II
- Regulation
- 21 CFR Part 862.1345
- Advisory Committee
- Clinical Chemistry
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The HiChem Glucose/HK Reagent Kit is an in vitro diagnostic reagent kit designed for the quantitative determination of glucose levels. It employs an enzymatic hexokinase method, where glucose is phosphorylated via hexokinase and ATP, enabling precise measurement of glucose concentrations in biological samples. This kit is classified under the device type 'Hexokinase, Glucose' and is intended for use in clinical chemistry applications.
The kit is supplied as a single-use reagent system for laboratory use and is intended for quantitative glucose measurement in serum, plasma, cerebrospinal fluid, and urine. It is regulated under the FDA 510(k) pathway (K960084) as a Class 2 device under product code CFR 862.1345. No information regarding sterility, MRI safety, or reusable components is provided in the specifications. Storage and handling instructions are not detailed beyond standard laboratory reagent protocols.
Other devices from Hi Chem, Inc.
Questions
AI-generated answers, 1 Oct 2026
What biological samples can the HiChem Glucose/HK Reagent Kit measure glucose in?
The HiChem Glucose/HK Reagent Kit is designed for quantitative glucose determination in serum, plasma, cerebrospinal fluid (CSF), and urine. This versatility makes it suitable for a range of clinical chemistry applications, including diabetes management, metabolic monitoring, and neurological diagnostics where glucose levels in non-blood samples may be relevant.
Is the HiChem Glucose/HK Reagent Kit intended for single-use or reusable applications?
The HiChem Glucose/HK Reagent Kit is explicitly supplied as a single-use reagent system for laboratory use. This design ensures consistency in measurement accuracy and reduces the risk of cross-contamination or degradation of reagents between uses, which is critical for reliable glucose testing in clinical settings.
How is the enzymatic hexokinase method in this kit different from other glucose testing methods?
The HiChem Glucose/HK Reagent Kit employs an enzymatic hexokinase method, where glucose reacts with hexokinase and ATP to produce glucose-6-phosphate. This biochemical reaction is highly specific to glucose and minimizes interference from other sugars (e.g., galactose or fructose), providing more accurate results compared to methods like glucose oxidase, which may be affected by certain antioxidants or uric acid. This precision is particularly valuable in clinical chemistry for diagnosing and managing conditions like diabetes.
What regulatory pathway does the HiChem Glucose/HK Reagent Kit follow, and what does that mean for users?
The HiChem Glucose/HK Reagent Kit is regulated under the FDA 510(k) pathway (K960084) as a Class 2 device under product code CFR 862.1345. This classification means it has undergone FDA review to demonstrate substantial equivalence to a legally marketed predicate device, ensuring it meets established performance standards for safety and effectiveness. Users can rely on this regulatory clearance as evidence of the kit’s compliance with U.S. clinical chemistry standards.
Are there any special storage requirements for the HiChem Glucose/HK Reagent Kit beyond standard laboratory protocols?
While the provided specifications do not detail specific storage instructions beyond standard laboratory reagent protocols, it is generally recommended to store enzymatic reagent kits like this one in a cool, dry place (2–8°C) away from direct light to preserve reagent stability. Exposure to extreme temperatures, humidity, or light can degrade enzymes (e.g., hexokinase) and compromise accuracy. Always follow the manufacturer’s accompanying documentation or contact HiChem, Inc. for precise handling guidance.