HIgH-Flo™ Needle Set RMS12414
Ref RMS12414Model High-Flo Subcutaneous Safety Needle Sets
HIgH-Flo™ Needle Set RMS12414 is a device classified as Class IIa in the EU and Class II in the US made by Repro Med Systems, Inc., registered in EUDAMED on 12 May 2026 (Basic UDI-DI B-00659443000568), cleared under FDA 510(k) K252015 on 28 Jan 2026 (4 earlier submissions) and listed in FDA GUDID since 19 Aug 2016 (UDI-DI 00659443000568), active as of 22 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-00659443000568 00659443000568 | Date12 May 2026 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK252015 | Date28 Jan 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00659443000568 | Date19 Aug 2016 | StatusListed |
Official records
- EUDAMED public site B-00659443000568
- AccessGUDID record 00659443000568
- FDA 510(k) database K252015
- FDA 510(k) database K214045
- FDA 510(k) database K200176
- FDA 510(k) database K211206
- FDA 510(k) database K122404
Across registries
- EUDAMED Basic UDI-DI B-00659443000568 registered 12 May 2026 Active
- FDA 510(k) K252015 decided 28 Jan 2026 Active
- FDA GUDID UDI-DI 00659443000568 listed 19 Aug 2016 Listed
Recalls
-
- Terminated Z-0051-2020
Mislabeled needle lengths
-
- Terminated Z-0318-2018
On 2/24/2016 during post sterilization inspection of part number F180 Precision Flow Rate Tubing, Lot number 1.042/16 the firm found 701 out of 3,195 were rejected due to visual defect, gap in the supplier s manufacturing seal for Part number #317036 5 X 6.5 ST Bag Combo. the firm decided to recall Precision Flow Rate Tubing and RMS HIgH-Flo Subcutaneous Safety Needles Sets due to the sterile barrier packaging being found to have gaps during post-sterilization inspection of one lot of flow tubing, in which 701 out of 3,195 units were rejected for not passing inspection. The firm determined that the issue was large than just the one lot and recalled the product via March 10, 2016 Voluntary Medical Device Corrections and Removal Notification to customers. The recall was conducted without FDA notification.
Timeline
- Cleared FDA 510(k) K122404
- Recall initiated FDA recalls Z-0318-2018
- Listed FDA GUDID 00659443000568
- Recall initiated FDA recalls Z-0051-2020
- Cleared FDA 510(k) K211206
- Cleared FDA 510(k) K200176
- Cleared FDA 510(k) K214045
- Cleared FDA 510(k) K252015
- Registered EUDAMED B-00659443000568
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- High-Flo Subcutaneous Safety Needle Sets EUDAMEDHIgH-Flo™ Needle Set GUDID
- Generic name
- Subcutaneous infusion/injection port needle
- Model / Ref / Catalog
- RMS12414, High-Flo Subcutaneous Safety Needle Sets
- Primary DI / UDI-DI
- 00659443000568
- Basic UDI-DI
- B-00659443000568
- FDA product code
- FPA
- EMDN code
- A010199 Needles for infusion and collection - other
- GMDN term
- Subcutaneous infusion/injection port needle
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 880.5440
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Radiation Sterilization
- MRI safety
- MR Unsafe
- Size
- Needle Gauge — 24 Gauge
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
| Sterilise before use | No | Yes |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Sterilise before use UDI-DI 00659443000568: EUDAMED states No, FDA GUDID states Yes.
Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Similar devices in this category
Other devices filed under NEEDLES FOR INFUSION AND COLLECTION - OTHER.
- Scalp vein set JLSVS963 by JianLin Medical Import&Export Co.,LTD
- IMPROSAFE® Multi-sample Needle 598421386 by GUANGZHOU IMPROVE MEDICAL INSTRUMENTS CO., LTD.
- IMPROSAFE® Multi-sample Needle 598422386 by GUANGZHOU IMPROVE MEDICAL INSTRUMENTS CO., LTD.
- SoftFil® Classic CS1870/N by SOFT MEDICAL AESTHETICS
- 106 Syringe 8010191 by M Dialysis AB
- SoftFil® Classic CS2240/L by SOFT MEDICAL AESTHETICS