by Siemens Medical Solutions USA, Inc.
Ref 11575216Model MDR_07_IIA_IQH_BTS LB A_ACDV_HLX_11575216
HLX Transducer 11575216 is an extracorporeal ultrasound imaging transducer (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Siemens Medical Solutions USA, Inc., registered in EUDAMED on 21 Sep 2026 (Basic UDI-DI 0405686902458W4), cleared under FDA 510(k) K242523 on 19 Nov 2024 and listed in FDA GUDID since 27 Nov 2024 (UDI-DI 04068151010022), active as of 24 Oct 2026.
Active
CE MDR 510(k)
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0405686902458W4 04068151010022 | Date21 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number04068151010022 | Date27 Nov 2024 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK242523 | Date19 Nov 2024 | StatusActive |
Official records
- EUDAMED public site 0405686902458W4
- AccessGUDID record 04068151010022
- FDA 510(k) database K242523
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 0405686902458W4 registered 21 Sep 2026 Active
- FDA 510(k) K242523 decided 19 Nov 2024 Active
- FDA GUDID UDI-DI 04068151010022 listed 27 Nov 2024 Listed
Timeline
- Cleared FDA 510(k) K242523
- Listed FDA GUDID 04068151010022
- Registered EUDAMED 0405686902458W4
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- HLX Transducer
- Generic name
- Extracorporeal ultrasound imaging transducer, hand-held
- Device name
- MDR_07_IIA_IQH_BTS Lb A_ACDV_HLX_11575216
- Model / reference
- 11575216, MDR_07_IIA_IQH_BTS LB A_ACDV_HLX_11575216
- Primary DI / UDI-DI
- 04068151010022
- Basic UDI-DI
- 0405686902458W4
- 510(k) Number
- FDA product code
- ITX
- EMDN code
- Z110402010101 Two–dimensional linear–array transcutaneous ultrasound probes
- GMDN term
- Extracorporeal ultrasound imaging transducer, hand-held
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1570
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under TWO–DIMENSIONAL LINEAR–ARRAY TRANSCUTANEOUS ULTRASOUND PROBES.
- SLAx/13-6 MHz P07699-80 by Fujifilm Sonosite, Inc.
- L442 04573596212073 by FUJIFILM CORPORATION
- LA332E 9600190000 by Esaote S.p.A.
- iLOOK P35003-10 by Fujifilm Sonosite, Inc.
- Linear probe L7-ES by CHISON Medical Technologies Co., Ltd.
- 18L5 Transducer 9070 by BK MEDICAL APS
- Linear probe L7-E by CHISON Medical Technologies Co., Ltd.
- LA532E 9600168000 by Esaote S.p.A.
- 14L3 Transducer 9051 by BK MEDICAL APS
- L6-12-RS H48062AC by GE Medical Systems CO. Ltd