Skip to content

Hoffmann 4935-0-030

by Stryker GmbH

Part of a family of 30 devices: see the family page

Ref 4935-0-030Model 08858251002862TG

Hoffmann 4935-0-030 is a medical device (EU MDR Class I; FDA Class II; FDA product code KTT, Appliance, Fixation, Nail/Blade/Plate Combination, Multiple Component; EMDN category external bone fixation systems) made by Stryker GmbH, registered in EUDAMED on 14 Jul 2026 (Basic UDI-DI 08858251002862TG), cleared under FDA 510(k) K233741 on 21 Dec 2023 (1 earlier submission) and listed in FDA GUDID since 31 May 2017 (UDI-DI 07613327294231), active as of 12 Nov 2026. 5 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

5 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 12 Nov 2026.

Regulatory status

as of registry sync 12 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number08858251002862TG Basic UDI-DI 07613327294231UDI-DIDate14 Jul 2026RegisteredStatusActive
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK233741 Date21 Dec 2023DecidedStatusActive
United StatesGUDID listing GUDID Number07613327294231 UDI-DI Date31 May 2017ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
LRF Hexapod Strut - Medium - Length 131-191mm
MRI safety
MR Unsafe
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 12 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 08858251002862TG registered 14 Jul 2026 Active
  • FDA 510(k) K233741 decided 21 Dec 2023 Active· +1 more in the status table
  • FDA GUDID UDI-DI 07613327294231 listed 31 May 2017 Listed

Recalls

5 recalls · FDA

  • 4 recalls, same reason

    • Terminated Z-0288-2019 FDA Class II initiated 28 Aug 2018
    • Terminated Z-0289-2019 FDA Class II initiated 28 Aug 2018
    • Terminated Z-0290-2019 FDA Class II initiated 28 Aug 2018
    • Terminated Z-0291-2019 FDA Class II initiated 28 Aug 2018

    The press fit connection of the Angular Sleeve and pin of the U-Joint and Click Lock did not meet specification. A dimensional discrepancy of the bore hole of the Angular Sleeve may cause a reduced press fit of the pin. This can result in partial of full displacement or loss of the pin and, accordingly, stability of the strut of the frame cannot be ensured.

    • Terminated Z-3240-2018 FDA Class II initiated 26 Jul 2018

    When creating a correction plan with the Correct Axial First button selected and the No. of corrections per day set to more than 1 (e.g., 2, 3, or 4), the Hexapod Software computes an erroneously accelerated correction plan for the axial portion of the plan.

Timeline

9 dated events

  1. Cleared FDA 510(k) K163656
  2. Listed FDA GUDID 07613327294231
  3. Recall initiated FDA recalls Z-3240-2018
  4. Recall initiated FDA recalls Z-0288-2019
  5. Recall initiated FDA recalls Z-0289-2019
  6. Recall initiated FDA recalls Z-0290-2019
  7. Recall initiated FDA recalls Z-0291-2019
  8. Cleared FDA 510(k) K233741
  9. Registered EUDAMED 08858251002862TG

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Hoffmann LRF™ EUDAMED
Hoffmann GUDID
Generic name
External orthopaedic fixation system noninvasive component, single-use
Device name
Hlrf - Struts - Class I - Non Sterile
Model / Ref / Catalog
4935-0-030, 08858251002862TG
Primary DI / UDI-DI
07613327294231
Basic UDI-DI
08858251002862TG
510(k) Number
FDA product code
KTT
EMDN code
P09120499 External bone fixation systems - other
GMDN term
External orthopaedic fixation system noninvasive component, single-use
Device class
Class I EUDAMED
Class II GUDID
Regulation number
888.3030
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
MRI safety
MR Unsafe

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class I
GUDID
Class II

Device class is stated on each registry's own scale: Class I in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under EXTERNAL BONE FIXATION SYSTEMS - OTHER.

Other devices from Stryker GmbH

See all devices from Stryker GmbH →

Properties

  • Sterilise before use
  • Single use
  • Prescription use
  • Lot / batch number
Other properties (21, all answered No)