# Hoffmann 4935-0-040

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/hoffmann-4935-0-040>
- Manufacturer: [Stryker GmbH](https://devicerts.com/manufacturers/stryker-gmbh) (Switzerland)
- Name in the registry: HOFFMANN 4935-0-040
- Device class: Class I (EU MDR); Class II (US FDA)
- FDA product code: KTT
- EMDN: P09120499 EXTERNAL BONE FIXATION SYSTEMS - OTHER
- GMDN: External orthopaedic fixation system noninvasive component, single-use (67571)

## Registrations and authorizations

- **EUDAMED** · CE/MDR · European Union · Basic UDI-DI 08858251002862TG · UDI-DI 07613327294200 · registered 2026-07-14 · status: Active
- **GUDID** · FDA 510(k) · United States · K233741 · decision 2023-12-21 · decision SESE · status: Active · from GUDID
- **GUDID** · GUDID listing · United States · UDI-DI 07613327294200 · listed 2017-05-31 · status: Listed (GUDID: in commercial distribution)
- **GUDID** · FDA 510(k) · United States · K163656 · decision 2017-04-14 · decision SESE · status: Active · from GUDID

## Recalls

- Z-0288-2019 · Class II · terminated · initiated 2018-08-28: The press fit connection of the Angular Sleeve and pin of the U-Joint and Click Lock did not meet specification. A dimensional discrepancy of the bore hole of the Angular Sleeve may cause a reduced press fit of the pin. This can result in partial of full displacement or loss of the pin and, accordingly, stability of the strut of the frame cannot be ensured.
- Z-0289-2019 · Class II · terminated · initiated 2018-08-28: The press fit connection of the Angular Sleeve and pin of the U-Joint and Click Lock did not meet specification. A dimensional discrepancy of the bore hole of the Angular Sleeve may cause a reduced press fit of the pin. This can result in partial of full displacement or loss of the pin and, accordingly, stability of the strut of the frame cannot be ensured.
- Z-0290-2019 · Class II · terminated · initiated 2018-08-28: The press fit connection of the Angular Sleeve and pin of the U-Joint and Click Lock did not meet specification. A dimensional discrepancy of the bore hole of the Angular Sleeve may cause a reduced press fit of the pin. This can result in partial of full displacement or loss of the pin and, accordingly, stability of the strut of the frame cannot be ensured.
- Z-0291-2019 · Class II · terminated · initiated 2018-08-28: The press fit connection of the Angular Sleeve and pin of the U-Joint and Click Lock did not meet specification. A dimensional discrepancy of the bore hole of the Angular Sleeve may cause a reduced press fit of the pin. This can result in partial of full displacement or loss of the pin and, accordingly, stability of the strut of the frame cannot be ensured.
- Z-3240-2018 · Class II · terminated · initiated 2018-07-26: When creating a correction plan with the Correct Axial First button selected and the No. of corrections per day set to more than 1 (e.g., 2, 3, or 4), the Hexapod Software computes an erroneously accelerated correction plan for the axial portion of the plan.

## Identity

- Trade name: Hoffmann LRF™ [EUDAMED]; HOFFMANN [FDA GUDID (AccessGUDID)]
- Generic name: External orthopaedic fixation system noninvasive component, single-use [FDA GUDID (AccessGUDID)]
- Device name: HLRF - STRUTS - CLASS I - NON STERILE [EUDAMED]
- Model / Ref / Catalog: 4935-0-040 [EUDAMED, FDA GUDID (AccessGUDID)]; 08858251002862TG [EUDAMED]

## Identifiers

- Primary DI / UDI-DI: 07613327294200 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 08858251002862TG [EUDAMED]
- 510(k) Number: K163656 [FDA GUDID (AccessGUDID)]; K233741 [FDA GUDID (AccessGUDID)]
- FDA product code: KTT [FDA GUDID (AccessGUDID)]
- EMDN code: P09120499 [EUDAMED]
- GMDN term: External orthopaedic fixation system noninvasive component, single-use (67571) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class I [EUDAMED]; Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 888.3030 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Netherlands [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Clinical & Handling

- Sterilisation method: Moist Heat or Steam Sterilization [FDA GUDID (AccessGUDID)]
- MRI safety: MR Unsafe [FDA GUDID (AccessGUDID)]

## Properties

- Sterilise before use: Yes [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Implantable: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reusable: No [EUDAMED]
- Contains latex: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Reprocessed single-use device: No [EUDAMED]
- Contains CMR substances (carcinogenic, mutagenic or toxic to reproduction): No [EUDAMED]
- Incorporates a substance derived from human blood or plasma: No [EUDAMED]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains endocrine-disrupting substances: No [EUDAMED]
- Administering medicine: No [EUDAMED]
- Measuring function: No [EUDAMED]
- Incorporates a medicinal substance: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Hoffmann 4935-0-040, Stryker GmbH. deviCERTS medical device catalogue. https://devicerts.com/devices/hoffmann-4935-0-040 (data as of 2026-11-28).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-11-12
- Statuses computed as of: 2026-11-28
- JSON: <https://devicerts.com/devices/hoffmann-4935-0-040.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/hoffmann-4935-0-040
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.