HS Nota
by H.S. Hospital Service SpA 14 variants
Ref HSNOTA14100-INModel HS NOTA
HS NOTA14100-IN is a side-notch biopsy gun handpiece/needle (EU MDD Class IIa; FDA Class II; FDA product code FCG, Biopsy Needle) made by H.S. Hospital Service SpA, registered in EUDAMED on 21 Aug 2026 (Basic UDI-DI B-08058983744789), cleared under FDA 510(k) K131925 on 10 Oct 2014 and listed in FDA GUDID since 1 Mar 2021 (UDI-DI 08058983744789), active as of 24 Oct 2026.
Active
CE MDD 510(k)
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-08058983744789 08058983744789 | Date21 Aug 2026 | StatusActive |
| United States | GUDID listing GUDID | Number08058983744789 | Date1 Mar 2021 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK131925 | Date10 Oct 2014 | StatusActive |
Official records
- EUDAMED public site B-08058983744789
- AccessGUDID record 08058983744789
- FDA 510(k) database K131925
From the FDA record
- Device description
- HS NOTA 14GX100MM WITH COAXIAL INTRODUCER
- MRI safety
- MR Unsafe
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-08058983744789 registered 21 Aug 2026 Active
- FDA 510(k) K131925 decided 10 Oct 2014 Active
- FDA GUDID UDI-DI 08058983744789 listed 1 Mar 2021 Listed
Timeline
- Cleared FDA 510(k) K131925
- Listed FDA GUDID 08058983744789
- Registered EUDAMED B-08058983744789
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Side-notch biopsy gun handpiece/needle
- Model / Ref / Catalog
- HS NOTA, HSNOTA14100-IN, HS NOTA14100-IN
- Primary DI / UDI-DI
- 08058983744789
- Basic UDI-DI
- B-08058983744789
- 510(k) Number
- FDA product code
- FCG
- EMDN code
- A0102010101 Shearing biopsy needles
- GMDN term
- Side-notch biopsy gun handpiece/needle
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 876.1075
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Italy
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Unsafe
- Size
- Needle Gauge — 14 GaugeLength — 100 MillimeterLength — 50 Millimeter
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under SHEARING BIOPSY NEEDLES AND KITS.