Humeral Head Plate With Angular Stability
by I.T.S. Implantat-Technologie-Systeme GmbH
510(k) K051412
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK051412 | Date11 Jul 2005 | StatusActive |
Recalls
-
- Ongoing Z-1594-2026
Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- HRS
- Device Class
- Class II
- Regulation
- 21 CFR Part 888.3030
- Advisory Committee
- Orthopedic
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 6 Oct 2026
The Humeral Head Plate with Angular Stability is a bone fixation system designed for the treatment of proximal humerus fractures. The device consists of a low-profile titanium plate and cancellous self-tapping stabilization screws to provide structural support to the bone.
This system is available in 4, 6, and 8-hole configurations to accommodate different fracture patterns. It has received FDA 510(k) clearance for use in orthopedic trauma surgery.
Other devices from I.T.S. Implantat-Technologie-Systeme GmbH
See all devices from I.T.S. Implantat-Technologie-Systeme GmbH →
Questions
AI-generated answers, 6 Oct 2026
What is the primary clinical indication for the Humeral Head Plate with Angular Stability?
The Humeral Head Plate with Angular Stability is indicated for the treatment of proximal humerus fractures. It functions as a bone fixation system that provides structural support to the bone during the healing process.
What plate configurations are available for this system?
The system is available in three distinct configurations featuring 4, 6, or 8 holes. This variety allows surgeons to select the appropriate plate size to accommodate different patient fracture patterns.
What materials and components are used in this fixation system?
The device is constructed from a low-profile titanium plate paired with cancellous self-tapping stabilization screws. This combination is designed to provide necessary structural support for orthopedic trauma surgery.
What is the regulatory status of this humeral fixation device?
This device has received FDA 510(k) clearance for use in orthopedic trauma surgery, as documented under submission K051412.