Ref 400-1102
Humeris Shoulder 400-1102 is a device of GMDN type shoulder glenoid fossa prosthesis (EU MDD Class III; FDA Class II; FDA product code KWT, Prosthesis, Shoulder, Non-Constrained, Metal/Polymer Cemented) made by Fx Solutions, registered in EUDAMED on 17 Jun 2026 (Basic UDI-DI B-03701037301708), cleared under FDA 510(k) K163669 on 17 May 2017 and listed in FDA GUDID since 22 May 2017 (UDI-DI 03701037301708), active as of 22 Oct 2026.
Active
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-03701037301708 03701037301708 | Date17 Jun 2026 | StatusActive |
| United States | GUDID listing GUDID | Number03701037301708 | Date22 May 2017 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK163669 | Date17 May 2017 | StatusActive |
Official records
- EUDAMED public site B-03701037301708
- AccessGUDID record 03701037301708
- FDA 510(k) database K163669
From the FDA record
- Device description
- 3-4 PEGS GLENOID PE CEMENTED SIZE S
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as containing natural rubber latex
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-03701037301708 registered 17 Jun 2026 Active
- FDA 510(k) K163669 decided 17 May 2017 Active
- FDA GUDID UDI-DI 03701037301708 listed 22 May 2017 Listed
Timeline
- Cleared FDA 510(k) K163669
- Listed FDA GUDID 03701037301708
- Registered EUDAMED B-03701037301708
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Humeris Shoulder
- Generic name
- Shoulder glenoid fossa prosthesis, prefabricated
- Model / Ref / Catalog
- 400-1102
- Primary DI / UDI-DI
- 03701037301708
- Basic UDI-DI
- B-03701037301708
- 510(k) Number
- FDA product code
- KWT
- EMDN code
- P09010303 Glenospheres
- GMDN term
- Shoulder glenoid fossa prosthesis, prefabricated
- Device class
- Class III EUDAMEDClass II GUDID
- Regulation number
- 888.3650
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class III | Class II |
| Contains latex | No | Yes |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Contains latex UDI-DI 03701037301708: EUDAMED states No, FDA GUDID states Yes.
Device class is stated on each registry's own scale: Class III in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.
Similar devices in this category
Other devices filed under GLENOSPHERES.
- SMR Shoulder Glenosphere 1374.09.111 by Limacorporate
- Shoulder System 04.01.0172 by Medacta International SA
- Shoulder - TiNbN Coating 04.01.0267 by Medacta International SA
- LINK Embrace Shoulder System 646-239/00 by Waldemar Link GmbH & Co. KG
- Reverse Glenoid Shoulder Head C38174202S by Tianjin Zhengtian Medical Instrument Co., Ltd.
- SMR System 1374.50.400 by Limacorporate
- LINK Embrace Shoulder System 646-239/03 by Waldemar Link GmbH & Co. KG
- MUTARS® 52101002 by implantcast GmbH