Skip to content

I-125 Seeds Code 6702

by Medi-Physics Inc. Dba Nycomed Amersham Imaging

510(k) K915156

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK915156 Date6 Jan 1992ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
KXK
Device Class
Class II
Regulation
21 CFR Part 892.5730
Advisory Committee
Radiology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The I-125 Seeds Code 6702 are a type of brachytherapy radionuclide source, designed for internal radiation therapy. These seeds emit low-energy gamma radiation from iodine-125, delivering targeted radiation to treat localized cancers, such as prostate cancer, with precision.

These seeds are supplied sterile and intended for single-use, requiring no reprocessing. They are classified as a Class II medical device under FDA regulations (892.5730) and were cleared via a 510(k) submission (K915156) in 1992. They are used in radiology settings and must be handled with care to ensure proper positioning and radiation safety.

Other devices from Medi-Physics Inc. Dba Nycomed Amersham Imaging

See all devices from Medi-Physics Inc. Dba Nycomed Amersham Imaging →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary clinical use for these I-125 seeds, and why are they considered a precision treatment option?

    The I-125 seeds are designed for brachytherapy, a form of internal radiation therapy used to treat localized cancers, most commonly prostate cancer. They emit low-energy gamma radiation from iodine-125, allowing precise delivery of radiation directly to the tumor site while minimizing exposure to surrounding healthy tissue. This targeted approach enhances treatment accuracy and reduces side effects compared to external radiation methods.

  • Are these seeds reusable, or are they intended for single-use only? How does this affect handling and safety?

    These I-125 seeds are sterile and intended for single-use only, requiring no reprocessing. This design ensures patient safety by preventing contamination or degradation from reuse, while also simplifying inventory management and reducing the risk of cross-contamination in clinical settings. Single-use also aligns with radiation safety protocols, as reprocessing could compromise the integrity of the radioactive source.

  • What regulatory pathway was followed for FDA clearance, and how does this relate to their classification as a Class II device?

    The I-125 seeds were cleared via a traditional 510(k) pathway (K915156) submitted in 1991, demonstrating substantial equivalence to a predicate device. They are classified as a Class II medical device (FDA code 892.5730) due to their role in delivering radiation therapy, which requires special controls to ensure safety and effectiveness. The 510(k) process confirms that the device meets performance standards for brachytherapy applications while adhering to FDA regulations for radiologic devices.

  • How should these seeds be stored, and what precautions should be taken given their radioactive nature?

    While the storage instructions aren’t explicitly detailed in the provided data, radioactive seeds like these must be stored in a secure, shielded container to prevent accidental exposure. They should be kept in a radiation-safe vault or lead-lined storage as per institutional protocols, away from unauthorized personnel. Handling requires adherence to radiation safety guidelines, including proper shielding, monitoring, and disposal procedures to comply with regulatory and occupational safety standards.