Skip to content

i-STAT 03P83-25

by Abbott Point of Care Inc.

Ref 03P83-25

i-STAT 03P83-25 is a device classified as IVD General (EU), Class II (US) made by Abbott Point of Care Inc., registered in EUDAMED on 1 Sep 2026 (Basic UDI-DI B-00054749000111), cleared under FDA 510(k) K894914 on 16 Oct 1989 and listed in FDA GUDID since 9 Sep 2016 (UDI-DI 00054749000111), active as of 23 Oct 2026. 5 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE IVDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

6 closed

Documents

None, self-declared

Class I: no certifier involved

510(k) K894914

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDD EUDAMED NumberB-00054749000111 Basic UDI-DI 00054749000111UDI-DIDate1 Sep 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00054749000111 UDI-DI Date9 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK894914 Date16 Oct 1989DecidedStatusActive

Official records

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00054749000111 registered 1 Sep 2026 Active
  • FDA 510(k) K894914 decided 16 Oct 1989 Active
  • FDA GUDID UDI-DI 00054749000111 listed 9 Sep 2016 Listed

Certificates

0 certificates · EUDAMED

No certifier certificate is listed. Devices of this class are self-declared by the manufacturer.

Recalls

6 recalls · FDA

    • Terminated Z-1540-2009 FDA Unclassified (pre-2012) initiated 23 Feb 2009 on shared 510(k) K894914

    Equipment problem: i-STAT cartridges were not properly sealed as the packaging system jammed, causing compromised seals.

  • 4 recalls, same reason

    • Terminated Z-0372-2008 FDA Unclassified (pre-2012) initiated 18 Oct 2007
    • Terminated Z-0375-2008 FDA Unclassified (pre-2012) initiated 18 Oct 2007
    • Terminated Z-0371-2008 FDA Unclassified (pre-2012) initiated 18 Oct 2007
    • Terminated Z-0374-2008 FDA Unclassified (pre-2012) initiated 18 Oct 2007

    Difficult to Close -- Certain lots of i-STAT cartridges are difficult to close, will not close or do not stay closed.

    • Terminated Z-1171-06 FDA Unclassified (pre-2012) initiated 24 May 2006

    Erroneous sodium and/or ionized calcium readings with a patient sample could be obtained

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

9 dated events

  1. Cleared FDA 510(k) K894914
  2. Recall initiated FDA recalls Z-1171-06
  3. Recall initiated FDA recalls Z-0372-2008
  4. Recall initiated FDA recalls Z-0375-2008
  5. Recall initiated FDA recalls Z-0371-2008
  6. Recall initiated FDA recalls Z-0374-2008
  7. Recall initiated FDA recalls Z-1540-2009
  8. Listed FDA GUDID 00054749000111
  9. Registered EUDAMED B-00054749000111

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
i-STAT
Generic name
Multiple blood gas/haemoximetry/electrolyte analyte IVD, reagent
Device name
i-STAT G Cartridge
Model / Ref / Catalog
03P83-25
Primary DI / UDI-DI
00054749000111 EUDAMED
10054749000118 GUDID
Basic UDI-DI
B-00054749000111
510(k) Number
FDA product code
JGS
EMDN code
W0101070202 Glucose - electrodes
GMDN term
Multiple blood gas/haemoximetry/electrolyte analyte IVD, reagent
Device class
Class IVD General EUDAMED
Class II GUDID
Regulation number
862.1665
EU registration type
Legacy device (under a directive)
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Primary DI / UDI-DIEUDAMED
00054749000111
GUDID
10054749000118
Device classEUDAMED
Class IVD General
GUDID
Class II

The registries describe this device under different primary UDI-DIs (EUDAMED lists 00054749000111; FDA GUDID lists 10054749000118), so their flags are not compared. Device class is stated on each registry's own scale: Class IVD General in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under ELECTRODES AND BIOSENSORS - LABORATORY.

Other devices from Abbott Point of Care Inc.

See all devices from Abbott Point of Care Inc. →

Properties

  • Single use
  • Contains latex
  • Near-patient testing
  • Professional testing
  • Lot / batch number
  • Expiration date
Other properties (20, all answered No)