I-Stat Portable Clinical Analyzer, Model 300

by I-Stat Corp. 510(k)

Active United States

510(k) K001387

Regulatory status

as of 27 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK001387 Date5 Oct 2000ClearedStatusActive

Coverage

1 jurisdiction

United States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of AmericaUnited States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not known
  • Not covered

United States — FDA 510(k) Active

Recalls

13 recalls · FDA

  • 6 recalls, same reason

    • Terminated Z-1974-2012 FDA Class II initiated 8 Sep 2011 via K001387, on the same 510(k)
    • Terminated Z-1978-2012 FDA Class II initiated 8 Sep 2011 via K001387, on the same 510(k)
    • Terminated Z-1973-2012 FDA Class II initiated 8 Sep 2011 via K001387, on the same 510(k)
    • Terminated Z-1976-2012 FDA Class II initiated 8 Sep 2011 via K001387, on the same 510(k)
    • Terminated Z-1975-2012 FDA Class II initiated 8 Sep 2011 via K001387, on the same 510(k)
    • Terminated Z-1977-2012 FDA Class II initiated 8 Sep 2011 via K001387, on the same 510(k)

    Some i-Stat Analyzers become uncomfortably hot to touch in the are of the battery. This is a recall extension.

  • 2 recalls, same reason

    • Terminated Z-0598-2011 FDA Unclassified (pre-2012) initiated 20 Sep 2010
    • Terminated Z-0597-2011 FDA Unclassified (pre-2012) initiated 20 Sep 2010

    i-STAT Analyzers batteries may overheat due to a circuitry failure, resulting in the analyzer becoming uncomfortably hot in the area of the battery component.

    • Terminated Z-2462-2010 FDA Unclassified (pre-2012) initiated 20 Aug 2010

    Reliability issues associated with broken connection pins within the downloader that mate with the pins from the analyzer.

    • Terminated Z-1133-2010 FDA Unclassified (pre-2012) initiated 6 Nov 2009

    Some Martel Printers used with the i-STAT 1 system have the potential of being damaged due to the use or rechargeable battery packs that do not contain a fuse.

    • Terminated Z-0865-2010 FDA Unclassified (pre-2012) initiated 29 Sep 2009 via K001387, on the same 510(k)

    Abbott Point of Care has determined that it is possible under certain circumstances that some test records could have their status update messages mis-matched with another record, resulting in the incorrect patient name, order number of comment being included in the CDS test record only.

    • Terminated Z-0812-2010 FDA Unclassified (pre-2012) initiated 9 Sep 2009

    The storage temperature on the label on the side of the i-Stat Portable Clinical Analyzer shipping box does not match product specification.

    • Terminated Z-2328-2009 FDA Unclassified (pre-2012) initiated 22 Apr 2009

    It appears that the rechargeable battery pack is overheating with or without the presence of smoke.

Recalls marked "via" name another device cleared under the same FDA submission as this one.

Specification

510(k)

510(k) Number
FDA Product Code
CGA
Device Class
Class II
Regulation
21 CFR Part 862.1345
Advisory Committee
Clinical Chemistry
FDA Decision
SESE Substantially Equivalent