Skip to content

IC9-RS

by GE Healthcare Austria GmbH & Co OG

Ref H48691PJModel IC9-RS

IC9-RS (H48691PJ) is a rectal/vaginal ultrasound imaging transducer (EU MDR Class IIa; FDA Class II) made by GE Healthcare Austria GmbH & Co OG, registered in EUDAMED on 26 Feb 2024 (Basic UDI-DI 8406821BUG00444HL), cleared under FDA 510(k) K230346 on 20 Jun 2023 (10 earlier submissions) and listed in FDA GUDID since 15 Jul 2016 (UDI-DI 00840682105026), active as of 24 Oct 2026. 5 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

4 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number8406821BUG00444HL Basic UDI-DI 00840682105026UDI-DIDate26 Feb 2024RegisteredStatusActive
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK230346 Date20 Jun 2023DecidedStatusActive
United StatesGUDID listing GUDID Number00840682105026 UDI-DI Date15 Jul 2016ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 8406821BUG00444HL registered 26 Feb 2024 Active
  • FDA 510(k) K230346 decided 20 Jun 2023 Active· +10 more in the status table
  • FDA GUDID UDI-DI 00840682105026 listed 15 Jul 2016 Listed

Recalls

5 recalls · 4 ongoing · FDA

  • 3 recalls, same reason

    • Ongoing Z-0155-2026 FDA Class II initiated 18 Sep 2025
    • Ongoing Z-0156-2026 FDA Class II initiated 18 Sep 2025
    • Ongoing Z-0157-2026 FDA Class II initiated 18 Sep 2025

    The Ultrasound-Guided Attenuation Parameter (UGAP) measurement data may display inaccurate values representing liver steatosis. This could potentially lead to inappropriate clinical decisions impacting overall care.

    • Ongoing Z-0865-2024 FDA Class II initiated 22 Dec 2023

    GE HealthCare has become aware of an issue with certain IC9-RS ultrasound probes (see Affected Products List) that can result in a double image artifact creating a ghost image with realistic features. An unrecognized artifact may lead to misdiagnosis.

    • Terminated Z-1965-2019 FDA Class II initiated 2 Jul 2019

    Potential for a transducer mis-alignment in certain transvaginal probes.

Timeline

18 dated events

  1. Cleared FDA 510(k) K203114
  2. Cleared FDA 510(k) K213642
  3. Cleared FDA 510(k) K213689
  4. Cleared FDA 510(k) K214039
  5. Cleared FDA 510(k) K230346
  6. Recall initiated FDA recalls Z-0865-2024
  7. Registered EUDAMED 8406821BUG00444HL
  8. Recall initiated FDA recalls Z-0155-2026
  9. Recall initiated FDA recalls Z-0156-2026
  10. Recall initiated FDA recalls Z-0157-2026

8 earlier events are in the sections above.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Rectal/vaginal ultrasound imaging transducer
Model / Ref / Catalog
IC9-RS, H48691PJ
Primary DI / UDI-DI
00840682105026
Basic UDI-DI
8406821BUG00444HL
Direct marketing DI
00840682105026
FDA product code
IYO, IYN, ITX
EMDN code
Z1104020202 Endocavitary ultrasound probes, multidimensional
GMDN term
Rectal/vaginal ultrasound imaging transducer
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1560, 892.1550, 892.1570
EU registration type
Standard device
EU market of registration
Austria
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
AT-MF-000001461

Similar devices in this category

Other devices filed under ENDOCAVITARY ULTRASOUND PROBES, MULTIDIMENSIONAL.

Other devices from GE Healthcare Austria GmbH & Co OG

See all devices from GE Healthcare Austria GmbH & Co OG →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)