ICU Medical CH3603
ICU Medical CH3603 is a medical device (FDA Class II; FDA product code FPA, Set, administration, intravascular) made by ICU Medical, Inc., cleared under FDA 510(k) K070532 on 20 Mar 2007 and listed in FDA GUDID since 27 Jul 2021 (UDI-DI 00887709081147), active as of 22 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
2 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00887709081147 | Date27 Jul 2021 | StatusListed |
| United States | FDA 510(k)SESE | NumberK070532 | Date20 Mar 2007 | StatusActive |
Official records
- AccessGUDID record 00887709081147
- FDA 510(k) database K070532
From the FDA record
- Device description
- 60” (152 cm) Appx 1.9 ml, Smallbore Ext Set w/MicroClave™ Clear, 0.2 Micron Low Protein Binding Filter, Spiros™ w/Red Cap, Clamp
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K070532 decided 20 Mar 2007 Active
- FDA GUDID UDI-DI 00887709081147 listed 27 Jul 2021 Listed
Recalls
-
- Ongoing Z-0699-2021
- Ongoing Z-0706-2021
Potential for spinning versions of male luers to exhibit leaks due to a molding defect. Fluid leakage may potentially cause delay of infusion, contamination of the fluid path, exposure to hazardous medications, blood loss, exposure to patient blood, or fluid path air-in-line.
Timeline
- Cleared FDA 510(k) K070532
- Recall initiated FDA recalls Z-0699-2021
- Recall initiated FDA recalls Z-0706-2021
- Listed FDA GUDID 00887709081147
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- ICU Medical
- Generic name
- Neutral-pressure intravenous line needleless valve-connector
- Model / Ref / Catalog
- CH3603
- Primary DI / UDI-DI
- 00887709081147
- 510(k) Number
- FDA product code
- FPA
- GMDN term
- Neutral-pressure intravenous line needleless valve-connector
- Device class
- Class II
- Regulation number
- 880.5440
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code FPA (Set, administration, intravascular).
- LOW PROFILE SAFSITE Y-SITE by B. Braun Medical, Inc.
- Merit Medical® 00884450029152 by Merit Medical Systems, Inc.
- CHURCHILL VENTED IV SET by Churchill Corp.
- SET, INTRAVASCULAR by PRIMROSE MEDICAL, INC.
- OPTFlow OPT32614 by EMED Technologies Corporation
- PHASEAL, SYSTEM FOR SEALED HANDLING OF CHEMOTHERAPEUTIC AGENTS by Quality System Consulting
- AMSafe® Extension Set 1 AE3107 by AMSINO INTERNATIONAL, INC.
- SAF-Q-112-G27 by EMED Technologies Corporation
- STRATO/INFUSAID PERIPORT INFUSION SET 41770, 41771 by Strato/Infusaid, Inc.
- DJF Intravascular Administration Set by Yangzhou Wei DE LI Trade Co., Ltd.