ICU Medical CH3606
ICU Medical CH3606 is an invasive blood pressure monitoring tubing set (FDA Class II; FDA product code FPA, Set, administration, intravascular) made by ICU Medical, Inc., cleared under FDA 510(k) K070532 on 20 Mar 2007 and listed in FDA GUDID since 27 Jul 2021 (UDI-DI 00887709081451), active as of 22 Oct 2026. 2 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
2 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00887709081451 | Date27 Jul 2021 | StatusListed |
| United States | FDA 510(k)SESE | NumberK070532 | Date20 Mar 2007 | StatusActive |
Official records
- AccessGUDID record 00887709081451
- FDA 510(k) database K070532
From the FDA record
- Device description
- Oncology Kit w/60" (152 cm) Appx 2.3 ml, Smallbore Ext Set w/Spiros™, Anti-Siphon Valve, ChemoClave™, Clamp, Rotating Luer; Double ChemoClave™ Syringe Transfer Set; Spiros™ w/Red Cap
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K070532 decided 20 Mar 2007 Active
- FDA GUDID UDI-DI 00887709081451 listed 27 Jul 2021 Listed
Recalls
-
- Ongoing Z-0704-2021
- Ongoing Z-0699-2021
Potential for spinning versions of male luers to exhibit leaks due to a molding defect. Fluid leakage may potentially cause delay of infusion, contamination of the fluid path, exposure to hazardous medications, blood loss, exposure to patient blood, or fluid path air-in-line.
Timeline
- Cleared FDA 510(k) K070532
- Recall initiated FDA recalls Z-0704-2021
- Recall initiated FDA recalls Z-0699-2021
- Listed FDA GUDID 00887709081451
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- ICU Medical
- Generic name
- Invasive blood pressure monitoring tubing set
- Model / Ref / Catalog
- CH3606
- Primary DI / UDI-DI
- 00887709081451
- 510(k) Number
- FDA product code
- FPA
- GMDN term
- Invasive blood pressure monitoring tubing set
- Device class
- Class II
- Regulation number
- 880.5440
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code FPA (Set, administration, intravascular).
- Micro Infusion Set by Deltec Systems, Inc.
- ACCESS. TO INTERAVACULAR ADMIN. SET by Tanner Corp.
- Cortez Needle Free IV Connector, Model MMD-001 by Mission Medicl Devices
- Centurion Pressure Injectable Extension Set by Centurion Medical Products
- AMSafe-3 Non-Vented I.V. Set with 10, 15, or 60 drops/ml Selectable Drip Chamber D38304 by AMSINO INTERNATIONAL, INC.
- Accu-Chek FlexLink Plus Infusion Set by Roche Diagnostics GmbH
- Angiographic Flush System by E-Z-Em, Inc.
- Vascular Access Port Continuous Infusion Sets by Florida Infusion Services, Inc.
- SAF-Q-109-G24-12 by EMED Technologies Corporation
- I.V. FREEDOM CLIP by Infection Control Products, Inc.