ID NOW™ Instrument EQ00200X
Ref NAT-000Model LFR-003 / LFR-004
ID NOW Instrument EQ00200X is an isothermal nucleic acid amplification analyser IVD (EU IVDR Class A; FDA Class II; FDA product code OOI, Real Time Nucleic Acid Amplification System) made by Alere Scarborough, Inc., registered in EUDAMED on 20 Oct 2026 (Basic UDI-DI 081187701IDN0001Z8), cleared under FDA 510(k) K141520 on 13 Jun 2014 and listed in FDA GUDID since 29 Oct 2018 (UDI-DI 00811877010593), active as of 24 Oct 2026.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/IVDR EUDAMED | Number081187701IDN0001Z8 00811877010593 | Date20 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00811877010593 | Date29 Oct 2018 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK141520 | Date13 Jun 2014 | StatusActive |
Official records
- EUDAMED public site 081187701IDN0001Z8
- AccessGUDID record 00811877010593
- FDA 510(k) database K141520
From the FDA record
- Device description
- The ID NOW™ Instrument is a portable, fluorescence based instrument intended to be used for the processing and analysis of Abbott molecular diagnostic assays.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 081187701IDN0001Z8 registered 20 Oct 2026 Active
- FDA 510(k) K141520 decided 13 Jun 2014 Active
- FDA GUDID UDI-DI 00811877010593 listed 29 Oct 2018 Listed
Recalls
-
- Terminated Z-1231-2017
Quidel Corporation is recalling Influenza Transport Swab Packages because it may include an incorrect sample swab mixed in with the proper swabs.
-
- Terminated Z-2095-2015
Risk of false negative results due to microbial growth in the Sample Receiver of one lot of the Alere i Influenza A & B kit
-
- Terminated Z-1677-2015
High invalid rate and an increased risk of false negative results with certain lots of the Alere i Influenza A & B kit.
Timeline
- Cleared FDA 510(k) K141520
- Recall initiated FDA recalls Z-1677-2015
- Recall initiated FDA recalls Z-2095-2015
- Recall initiated FDA recalls Z-1231-2017
- Listed FDA GUDID 00811877010593
- Registered EUDAMED 081187701IDN0001Z8
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- ID NOW™ Instrument (OUS) EUDAMEDID NOW™ Instrument GUDID
- Generic name
- Isothermal nucleic acid amplification analyser IVD, laboratory
- Model / reference
- LFR-003 / LFR-004 EUDAMEDNAT-000 EUDAMEDEQ00200X GUDID
- Primary DI / UDI-DI
- 00811877010593
- Basic UDI-DI
- 081187701IDN0001Z8
- 510(k) Number
- FDA product code
- OOI
- EMDN code
- W0201020201 Immunochemistry readers
- GMDN term
- Isothermal nucleic acid amplification analyser IVD, laboratory
- Device class
- Class A EUDAMEDClass II GUDID
- Regulation number
- 862.2570
- EU registration type
- Standard device
- EU market of registration
- Ireland
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | LFR-003 / LFR-004 NAT-000 | EQ00200X |
| Device class | Class A | Class II |
Similar devices in this category
Other devices filed under IMMUNOCHEMISTRY READERS.
- RIDA®Q3 ZRQ3 by R-Biopharm AG
- NeoEldex® ELISA Analyzer IN009 by MONOBIND, INC.
- Fluorescence Immunoassay Analyzer AFR-702 by Hangzhou Alltest Biotech.Co.,Ltd.
- PrisMatic® ELISA Analyzer IN013 by MONOBIND, INC.
- Dry-type Fluorescent Immunoassay Analyzer AFR-ACO600 by ACRO BIOTECH Inc.
- INFINITE F50 PLUS 30183570 by Tecan Austria GmbH
- Cube Reader CUBE-802 by opTricon GmbH
- Fluorescence Immunoassay Analyzer ACA205 by ACRO BIOTECH Inc.
- Elisa Microplate Reader BS005 by Biobase Biodustry(Shandong) Co.,Ltd.
- AFIAS-50 FPRR022 by Boditech Med, Inc.