iFlow
by ZOLL Medical Corporation 2 variants
Ref 301.328.020-40
iFlow (301.328.020-40) is a breathing circuit gas-sampling/monitoring set (EU MDR Class IIa; FDA Class II; FDA product code CBK, Ventilator, Continuous, Facility Use) made by Zoll Medical Corporation, registered in EUDAMED on 7 Jul 2026 (Basic UDI-DI 08479460BFBQ), cleared under FDA 510(k) K183364 on 13 Sep 2019 and listed in FDA GUDID since 24 Jun 2026 (UDI-DI 00198843001145), active as of 23 Oct 2026. 3 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number08479460BFBQ 00198843001145 | Date7 Jul 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00198843001145 | Date24 Jun 2026 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK183364 | Date13 Sep 2019 | StatusActive |
Official records
- EUDAMED public site 08479460BFBQ
- AccessGUDID record 00198843001145
- FDA 510(k) database K183364
From the FDA record
- Device description
- iFlow 200 S plus Adult / Pediatric Proximal Flow Sensor, SPU, 10 pc, Global
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 08479460BFBQ registered 7 Jul 2026 Active
- FDA 510(k) K183364 decided 13 Sep 2019 Active
- FDA GUDID UDI-DI 00198843001145 listed 24 Jun 2026 Listed
Recalls
-
- Completed Z-1967-2023
- Completed Z-1966-2023
Vyaire Medical identified two patient safety risks during the use of the bellavista 1000 and bellavista 1000e: 1. Under certain conditions of use, the touchscreen may become unresponsive and the device application stops responding (APP Hang). When this occurs, if the user continues to interact with the touchscreen, a message will appear that states DeviceSoftware.Application is not responding or a decommission screen will appear on the user interface. The ventilator will issue both an audible and visual alarm. Ventilation continues without interruption with the settings applied prior to the APP Hang error. 2. The potential for a use error has been identified if the operator applies the proposed settings without confirming the settings are suitable for the patient.
-
- Terminated Z-0622-2022
Potential cessation in ventilation can occur under specific conditions.
Timeline
- Cleared FDA 510(k) K183364
- Recall initiated FDA recalls Z-0622-2022
- Recall initiated FDA recalls Z-1967-2023
- Recall initiated FDA recalls Z-1966-2023
- Listed FDA GUDID 00198843001145
- Registered EUDAMED 08479460BFBQ
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- bellavista
- Generic name
- Breathing circuit gas-sampling/monitoring set
- Device name
- iFlow
- Model / reference
- 301.328.020-40
- Primary DI / UDI-DI
- 00198843001145
- Basic UDI-DI
- 08479460BFBQ
- 510(k) Number
- FDA product code
- CBK
- EMDN code
- Z1203019085 Various instruments for anaesthesia and pulmonary ventilation support - consumables
- GMDN term
- Breathing circuit gas-sampling/monitoring set
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 868.5895
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Manufacturer details
- EUDAMED SRN
- US-MF-000021386
- Authorised representative
- ZOLL International Holding B.V. NL-AR-000012554
Similar devices in this category
Other devices filed under VARIOUS INSTRUMENTS FOR ANAESTHESIA AND PULMONARY VENTILATION SUPPORT - CONSUMABLES.
- Infinity ID CLIC Absorber Free MX50120 by Drägerwerk AG & Co. KGaA
- CLIC adapter MX50090 by Drägerwerk AG & Co. KGaA
- DRAIN, TEE TNC-ED-WT001 by Orantech Inc.
- Temperature flow probe TSF-FP02-24 by Orantech Inc.
- Surfactant Catheter 9 Fr Angle 921 014 051 by DİSPOSET TIBBİ ÜRÜNLER SANAYİ VE TİCARET ANONİM ŞİRKETİ
- FlowSense A0000047 by ARCHEON