# Impella 5.0 AIC Pump Set

> Listed: FDA GUDID listing, not in commercial distribution. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/impella-005062>
- Manufacturer: [Abiomed, Inc.](https://devicerts.com/manufacturers/abiomed-inc) (United States)
- Device class: Class II (US FDA)
- FDA product code: KFM, OZD
- GMDN: Intracardiac circulatory assist axial-pump catheter (56732)

## Registrations and authorizations

- **GUDID** · GUDID listing · United States · UDI-DI 00813502011180 · listed 2014-07-31 · status: Listed (GUDID: not in commercial distribution)

## Recalls

- Z-0980-2024 · Class I · ongoing · initiated 2023-12-27: IFU has been updated to include warnings about the risk of the inlet perforating through the myocardial wall of the left ventricle due to operator handling.
- Z-1074-2024 · Class II · ongoing · initiated 2023-12-27: New warnings are being added to the Instructions for Use for all affected products to reduce the possibility of fibers being drawn into the Impella, which may result in low flow of the device.
- Z-2112-2023 · Class I · ongoing · initiated 2023-06-14: There is a potential risk for unintentional interaction of the Impella motor housing with the distal stent of a transcatheter aortic valve replacement (TAVR) resulting in destruction of the impeller blades. This has resulted in low flow from the damaged Impella system. Systemic embolization of the fractured impeller material is a possibility.

## Identity

- Trade name: Impella [FDA GUDID (AccessGUDID)]
- Generic name: Intracardiac circulatory assist axial-pump catheter [FDA GUDID (AccessGUDID)]
- Model / Ref / Catalog: Impella 5.0 AIC Pump Set [FDA GUDID (AccessGUDID)]; 005062 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00813502011180 [FDA GUDID (AccessGUDID)]
- FDA product code: KFM [FDA GUDID (AccessGUDID)]; OZD [FDA GUDID (AccessGUDID)]
- GMDN term: Intracardiac circulatory assist axial-pump catheter (56732) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class II [FDA GUDID (AccessGUDID)]
- Regulation number: 870.4360 [FDA GUDID (AccessGUDID)]
- GUDID distribution status: Not in Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Supplied sterile: Yes [FDA GUDID (AccessGUDID)]
- Single use: Yes [FDA GUDID (AccessGUDID)]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Convenience kit: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Sterilise before use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [FDA GUDID (AccessGUDID)]
- Contains latex: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Impella 5.0 AIC Pump Set, Abiomed, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/impella-005062 (data as of 2026-11-27).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-27
- JSON: <https://devicerts.com/devices/impella-005062.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/impella-005062
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.
