Implant Prosthetics 9003751
by PREAT Corporation 2 variants
Implant Prosthetics 9003751 is a Class II device made by PREAT Corporation, cleared under FDA 510(k) K220823 on 26 Oct 2022 (1 earlier submission) and listed in FDA GUDID since 1 Sep 2022 (UDI-DI 00842092165287), active as of 22 Oct 2026. 9 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
9 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK220823 | Date26 Oct 2022 | StatusActive |
| United States | GUDID listing | Number00842092165287 | Date1 Sep 2022 | StatusListed |
Official records
- AccessGUDID record 00842092165287
- FDA 510(k) database K220823
- FDA 510(k) database K183518
Across registries
- FDA 510(k) K220823 decided 26 Oct 2022 Active
- FDA GUDID UDI-DI 00842092165287 listed 1 Sep 2022 Listed
Recalls
-
- Ongoing Z-2514-2025
Engaging titanium base was manufactured 180 degrees around the post from where it should be located in relation to the connection geometry; if the flat is on the wrong side of the post, the crown will not fit onto the abutment in the correct orientation, resulting in restoration delay.
-
- Ongoing Z-2107-2025
Due to manufacturing error, digital analog rotational feature is 180 degrees off.
-
- Ongoing Z-1987-2025
Due to manufacturing issues, abutment products were manufactured with screw seat located too high, which may cause the mating screw to have a shorter engagement length into the associated implant.
-
- Ongoing Z-2318-2024
Due to incorrect milled titanium abutment being packaged and labeled.
-
- Ongoing Z-1321-2024
Due to a manufacturing issue, the screw seat location on the abutment product may be too high, causing mating screw to have a shorter engagement length into the associated implant.
-
- Ongoing Z-0153-2024
- Ongoing Z-0154-2024
- Ongoing Z-0152-2024
The healing abutments contain a dimensional condition that may lead to a gap between the healing abutment and the implant allowing for microleakage
-
- Ongoing Z-1285-2023
Engaging titanium base contains a dimensional condition that allows vertical movement of the titanium base after the prosthetic screw is torqued to the recommended value, which if undetected and installed on the implant, may lead to abutment/screw fracture, which could result in the abutment/screw/crown being ingested by the patient.
Timeline
- Cleared FDA 510(k) K220823
- Recall initiated FDA recalls Z-1285-2023
- Recall initiated FDA recalls Z-0153-2024
- Recall initiated FDA recalls Z-0154-2024
- Recall initiated FDA recalls Z-0152-2024
- Recall initiated FDA recalls Z-1321-2024
- Recall initiated FDA recalls Z-2318-2024
- Recall initiated FDA recalls Z-1987-2025
- Recall initiated FDA recalls Z-2107-2025
- Recall initiated FDA recalls Z-2514-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Implant Prosthetics
- Generic name
- Dental prosthesis/implant abutment screw
- Model / Ref / Catalog
- 9003751
- Primary DI / UDI-DI
- 00842092165287
- FDA product code
- NHA
- GMDN term
- Dental prosthesis/implant abutment screw
- Device class
- Class II
- Regulation number
- 872.3630
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
- MRI safety
- MR Conditional