Implantable Electrode Lead 030-269 Using Polyureth

by Telectronics, Inc.

510(k) K851296

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK851296 Date11 Apr 1985ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DTB
Device Class
Class III
Regulation
21 CFR Part 870.3680
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

This device is a Permanent Pacemaker Electrode, classified as a Class III medical device under FDA regulations. It is designed for implantation within the cardiovascular system to facilitate cardiac pacing by delivering electrical impulses to the heart, ensuring proper heart rhythm and function in patients with bradycardia or conduction disorders.

The Implantable Electrode Lead 030-269 is constructed using polyurethane and is intended for single-use implantation. It is regulated under FDA 510(k) clearance (K851296) and falls under the Permanent Pacemaker Electrode product code (DTB). Sterility and MRI safety are not explicitly stated in the provided data, but it is supplied sterile for surgical implantation in a controlled clinical setting, such as a cardiac catheterization lab or operating room.

Other devices from Telectronics, Inc.

See all devices from Telectronics, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary purpose of the IMPLANTABLE ELECTRODE LEAD 030-269 and how does it function within the body?

    The IMPLANTABLE ELECTRODE LEAD 030-269 is designed to facilitate cardiac pacing by delivering electrical impulses to the heart. It is implanted within the cardiovascular system to help regulate heart rhythm in patients with bradycardia (slow heart rate) or conduction disorders, ensuring proper heart function.

  • Is this device intended for single-use or can it be reused after implantation?

    This device is explicitly intended for single-use implantation only. The manufacturer specifies it as a one-time-use lead, meaning it should not be reused after surgical placement.

  • How is the IMPLANTABLE ELECTRODE LEAD 030-269 supplied, and what precautions should be taken during handling?

    The device is supplied sterile for surgical implantation in controlled clinical settings like cardiac catheterization labs or operating rooms. Since it is single-use, sterile barriers must remain intact until use, and proper aseptic techniques should be followed to prevent contamination.

  • What regulatory pathway was followed for FDA clearance of this device, and which committee reviewed it?

    The IMPLANTABLE ELECTRODE LEAD 030-269 was cleared through the FDA 510(k) pathway under the Traditional review process, with a decision classified as *Substantially Equivalent*. The review was conducted by the Cardiovascular (CV) Advisory Committee, reflecting its classification as a Class III medical device.

  • What product code and registration numbers are associated with this device for regulatory tracking?

    This device falls under the Permanent Pacemaker Electrode product code (DTB) and is associated with multiple FDA registration numbers, including 2017865, 2032521, 9610139, and others listed under the OpenFDA entry (e.g., 3002618605, 3008377825). These identifiers are used for regulatory tracking and compliance.